Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Comparative pullout behavior of half-hooked and commercial steel fibers embedded in UHPC under static and impact loads

Full metadata record
DC Field Value Language
dc.contributor.authorYoo, Doo-Yeol-
dc.contributor.authorKim, Soonho-
dc.date.accessioned2022-07-10T01:10:11Z-
dc.date.available2022-07-10T01:10:11Z-
dc.date.created2021-05-12-
dc.date.issued2019-03-
dc.identifier.issn0958-9465-
dc.identifier.urihttps://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/148200-
dc.description.abstractThis study investigates the pullout behaviors of various steel fibers embedded in ultra-high-performance concrete (UHPC) under static and impact loading conditions. For this purpose, four types of steel fibers, i.e., straight, hooked, twisted, and half-hooked, and three different loading rates applied by static and impact pullout test machines were adopted. To examine the effect of inclination angle on the pullout behavior, four different inclination angles of 0, 30, 45, and 60 were considered. Test results indicate that the highest average bond strengths were found for the hooked and twisted fibers for static and impact loads, respectively, whereas the straight fibers exhibited the lowest bond strength at all inclination angles. The effectiveness of using half-hooked fibers increased when they were inclined, and maximized at an inclination angle of 45 compared to straight and highly deformed fibers. The use of the twisted and half-hooked fibers was also more effective in static pullout energies than the hooked and straight fibers. The pullout resistance of all the steel fibers in UHPC was improved under impact loading conditions, and the order of the loading rate effectiveness regarding both the average bond strength and pullout energy was as follows: straight fibers > half-hooked fibers > twisted fibers > hooked fibers. The change in the failure mode from pullout to rupture, due to the increase in the loading rate, adversely affected the rate sensitivity of the bond strength and energy absorption capacity. Since the deformed steel fibers were easily ruptured under impact loads, their rupture failure needs to be prevented to achieve an excellent bond strength and energy absorption capacity.-
dc.language영어-
dc.language.isoen-
dc.publisherELSEVIER SCI LTD-
dc.titleComparative pullout behavior of half-hooked and commercial steel fibers embedded in UHPC under static and impact loads-
dc.typeArticle-
dc.contributor.affiliatedAuthorYoo, Doo-Yeol-
dc.identifier.doi10.1016/j.cemconcomp.2018.12.023-
dc.identifier.scopusid2-s2.0-85059339899-
dc.identifier.wosid000459358700009-
dc.identifier.bibliographicCitationCement and Concrete Composites, v.97, pp.89 - 106-
dc.relation.isPartOfCement and Concrete Composites-
dc.citation.titleCement and Concrete Composites-
dc.citation.volume97-
dc.citation.startPage89-
dc.citation.endPage106-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaConstruction & Building Technology-
dc.relation.journalResearchAreaMaterials Science-
dc.relation.journalWebOfScienceCategoryConstruction & Building Technology-
dc.relation.journalWebOfScienceCategoryMaterials Science, Composites-
dc.subject.keywordPlusHIGH-PERFORMANCE CONCRETE-
dc.subject.keywordPlusCEMENTITIOUS COMPOSITES-
dc.subject.keywordPlusFLEXURAL BEHAVIOR-
dc.subject.keywordPlusSTRAIN-RATE-
dc.subject.keywordPlusSTRENGTH-
dc.subject.keywordPlusTENSILE-
dc.subject.keywordAuthorUltra-high-performance concrete-
dc.subject.keywordAuthorSteel fibers-
dc.subject.keywordAuthorPullout resistance-
dc.subject.keywordAuthorImpact-
dc.subject.keywordAuthorRate sensitivity-
dc.subject.keywordAuthorDynamic increase factor-
dc.identifier.urlhttps://www.sciencedirect.com/science/article/pii/S0958946518308497?via%3Dihub-
Files in This Item
Go to Link
Appears in
Collections
서울 공과대학 > 서울 건축공학부 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Yoo, Doo Yeol photo

Yoo, Doo Yeol
COLLEGE OF ENGINEERING (SCHOOL OF ARCHITECTURAL ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE