Diagnostic Reference Levels for Adult Nuclear Medicine Imaging Established from the National Survey in Korea
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Song, Ho-Chun | - |
dc.contributor.author | Na, Myung Hwan | - |
dc.contributor.author | Kim, Jahae | - |
dc.contributor.author | Cho, Sang-Geon | - |
dc.contributor.author | Park, Jin Kyung | - |
dc.contributor.author | Kang, Keon-Wook | - |
dc.contributor.author | Kim, Min-Woo | - |
dc.contributor.author | Kim, Byung Il | - |
dc.contributor.author | Kim, Seong-Min | - |
dc.contributor.author | Nam, Hyun-Yeol | - |
dc.contributor.author | Ryu, Jin-Sook | - |
dc.contributor.author | Seok, Ju Won | - |
dc.contributor.author | Ahn, Byeong-Cheol | - |
dc.contributor.author | Oh, Sun Young | - |
dc.contributor.author | Ryu, Young Hoon | - |
dc.contributor.author | Yoo, Ie Ryung | - |
dc.contributor.author | Lee, Yukyung | - |
dc.contributor.author | Lim, Seok Tae | - |
dc.contributor.author | Cho, Ihnho | - |
dc.contributor.author | Choi, Yun Young | - |
dc.contributor.author | Choi, Joon Young | - |
dc.contributor.author | Choi, Seung Jin | - |
dc.contributor.author | Kim, Tae-Sung | - |
dc.contributor.author | Lee, Eun Jeong | - |
dc.contributor.author | Jeong, Young Jin | - |
dc.contributor.author | Heo, Young-Jun | - |
dc.date.accessioned | 2022-07-10T14:51:16Z | - |
dc.date.available | 2022-07-10T14:51:16Z | - |
dc.date.created | 2021-05-11 | - |
dc.date.issued | 2019-02 | - |
dc.identifier.issn | 1869-3474 | - |
dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/148432 | - |
dc.description.abstract | PurposeThere is substantial need for optimizing radiation protection in nuclear medicine imaging studies. However, the diagnostic reference levels (DRLs) have not yet been established for nuclear medicine imaging studies in Korea.Materials and MethodsThe data of administered activity in 32 nuclear medicine imaging studies were collected from the Korean Society of Nuclear Medicine (KSNM) dose survey database from 2013 and 2014. Through the expert discussions and statistical analyses, the 75th quartile value (Q3) was suggested as the preliminary DRL values. Preliminary DRLs were subjected to approval process by the KSNM Board of Directors and KSNM Council, followed by clinical applications and performance rating by domestic institutes.ResultsDRLs were determined through 32 nuclear medicine imaging studies. The Q3 value was considered as appropriate selection as it was generally consistent with the most commonly administered activity. In the present study, the final version of initial DRL values for nuclear medicine imaging in Korean adults is described including various protocols of the brain and myocardial perfusion imaging.ConclusionThe first DRLs for nuclear medicine imaging in Korean adults were confirmed. The DRLs will enable optimized radiation protection in the field of nuclear medicine imaging in Korea. | - |
dc.language | 영어 | - |
dc.language.iso | en | - |
dc.publisher | SPRINGER HEIDELBERG | - |
dc.title | Diagnostic Reference Levels for Adult Nuclear Medicine Imaging Established from the National Survey in Korea | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Choi, Yun Young | - |
dc.identifier.doi | 10.1007/s13139-019-00585-y | - |
dc.identifier.scopusid | 2-s2.0-85061672496 | - |
dc.identifier.wosid | 000458995000012 | - |
dc.identifier.bibliographicCitation | NUCLEAR MEDICINE AND MOLECULAR IMAGING, v.53, no.1, pp.64 - 70 | - |
dc.relation.isPartOf | NUCLEAR MEDICINE AND MOLECULAR IMAGING | - |
dc.citation.title | NUCLEAR MEDICINE AND MOLECULAR IMAGING | - |
dc.citation.volume | 53 | - |
dc.citation.number | 1 | - |
dc.citation.startPage | 64 | - |
dc.citation.endPage | 70 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.identifier.kciid | ART002437556 | - |
dc.description.journalClass | 1 | - |
dc.description.isOpenAccess | Y | - |
dc.description.journalRegisteredClass | scopus | - |
dc.description.journalRegisteredClass | kci | - |
dc.relation.journalResearchArea | Radiology, Nuclear Medicine & Medical Imaging | - |
dc.relation.journalWebOfScienceCategory | Radiology, Nuclear Medicine & Medical Imaging | - |
dc.subject.keywordPlus | DOSE REFERENCE LEVELS | - |
dc.subject.keywordPlus | COMPUTED-TOMOGRAPHY | - |
dc.subject.keywordPlus | RADIOLOGY | - |
dc.subject.keywordAuthor | Diagnostic reference level | - |
dc.subject.keywordAuthor | Radiopharmaceutical | - |
dc.subject.keywordAuthor | Dose optimization | - |
dc.subject.keywordAuthor | Nuclear medicine imaging | - |
dc.identifier.url | https://link.springer.com/article/10.1007%2Fs13139-019-00585-y | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1365
COPYRIGHT © 2021 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.