Cited 0 time in
유기 랭킨 사이클 기반 제습 증발냉각 공조시스템의 1차 에너지 절감효과
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | 동혜원 | - |
| dc.contributor.author | 박준영 | - |
| dc.contributor.author | 이수진 | - |
| dc.contributor.author | 정재원 | - |
| dc.date.accessioned | 2022-07-10T22:55:37Z | - |
| dc.date.available | 2022-07-10T22:55:37Z | - |
| dc.date.created | 2021-05-14 | - |
| dc.date.issued | 2018-11 | - |
| dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/148949 | - |
| dc.description.abstract | This research evaluates the impact of an organic Rankine cycle (ORC) powered by various heat sources on enhancing the primary energy saving potential of a liquid desiccant and indirect and direct evaporative cooling-assisted 100% outdoor air system (LD-IDECOAS). The liquid desiccant used for dehumidification of the process air needs regeneration that in turn requires a low-grade heat, preferably waste heat from a combined heat and power (CHP) system, to maximize the energy benefits in this thermally driven air condition system. Considering that ORC is a promising CHP system, we applied a solar thermal system and a district heat source, respectively, to a 2-kW ORC integrated with an LD-IDECOAS to build two system cases for a comparative study. The primary energy consumption of each system case was estimated and compared using detailed energy simulation. The results of the analyses show that the ORC-integrated LD-IDECOAS powered by the district heat source exhibits the best primary energy saving potential (i.e., 35%). | - |
| dc.language | 한국어 | - |
| dc.language.iso | ko | - |
| dc.publisher | (사)한국건축친환경설비학회 | - |
| dc.title | 유기 랭킨 사이클 기반 제습 증발냉각 공조시스템의 1차 에너지 절감효과 | - |
| dc.title.alternative | Primary Energy Savings of a Organic Rankine Cycle in a Liquid Desiccant and Evaporative Cooling-assisted Air Conditioning System | - |
| dc.type | Article | - |
| dc.contributor.affiliatedAuthor | 정재원 | - |
| dc.identifier.bibliographicCitation | 한국건축친환경설비학회 추계학술발표대회 논문집, pp.127 - 128 | - |
| dc.relation.isPartOf | 한국건축친환경설비학회 추계학술발표대회 논문집 | - |
| dc.citation.title | 한국건축친환경설비학회 추계학술발표대회 논문집 | - |
| dc.citation.startPage | 127 | - |
| dc.citation.endPage | 128 | - |
| dc.type.rims | ART | - |
| dc.type.docType | Proceeding | - |
| dc.description.journalClass | 2 | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | other | - |
| dc.subject.keywordAuthor | 유기 랭킨 사이클 | - |
| dc.subject.keywordAuthor | 액체식 제습시스템 | - |
| dc.subject.keywordAuthor | 증발냉각 시스템 | - |
| dc.subject.keywordAuthor | 열병합 발전 | - |
| dc.subject.keywordAuthor | Organic Rankine cycle | - |
| dc.subject.keywordAuthor | Liquid desiccant | - |
| dc.subject.keywordAuthor | Evaporative cooler | - |
| dc.subject.keywordAuthor | Combined heat and power | - |
| dc.identifier.url | https://www.auric.or.kr/User/Rdoc/DocRdoc.aspx?returnVal=RD_R&dn=380436#.YSWgOt9t-Uk | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1366
COPYRIGHT © 2024 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.
