Cited 0 time in
Removal Effect of Bio-contaminants in a Packaged Liquid Desiccant-assisted Air Conditioning Unit
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Dong, Hye-Won | - |
| dc.contributor.author | Jeong, Jae Weon | - |
| dc.date.accessioned | 2022-07-11T15:45:06Z | - |
| dc.date.available | 2022-07-11T15:45:06Z | - |
| dc.date.created | 2021-05-14 | - |
| dc.date.issued | 2018-07 | - |
| dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/149663 | - |
| dc.description.abstract | The purpose of the study is to evaluate the removal effects of microbial contamination, such as fungi and bacteria, on a packaged liquid desiccant-assisted air conditioning unit. Recently, a package unit of a liquid desiccant and indirect and direct evaporative cooling-assisted 100% outdoor air system (LD-IDECOAS) was proposed. The LDIDECOAS consists of a liquid desiccant system, an indirect evaporative cooler, and a direct evaporative cooler. The test was conducted under operating conditions during the cooling season when the LD-IDECOAS operates a liquid desiccant system, an indirect evaporative cooler, and a direct evaporative cooler. The sampling is performed ate the inlet (outdoor air) and outlet (supply air) of the package unit. Fungi were cultured in a potato dextrose agar (PDA) medium, and bacteria were cultured in a tryptic soy agar (TSA) medium as indices of bio-contaminants. The results indicated that the concentration of fungal contamination in the supply air (that passes through the package unit) decreased by 7.7% when compared to that of outdoor air. The concentration of bacterial contamination in the outlet was also reduced by 72.4% when compared to that in the inlet. Hence, the package unit improves air quality by removing bio-contaminants, such as fungi and bacteria, although unexpected contamination occurred in the experiment. | - |
| dc.language | 영어 | - |
| dc.language.iso | en | - |
| dc.publisher | Purdue University | - |
| dc.title | Removal Effect of Bio-contaminants in a Packaged Liquid Desiccant-assisted Air Conditioning Unit | - |
| dc.type | Article | - |
| dc.contributor.affiliatedAuthor | Jeong, Jae Weon | - |
| dc.identifier.bibliographicCitation | 2018 Purdue Conference Proceedings, pp.1 - 10 | - |
| dc.relation.isPartOf | 2018 Purdue Conference Proceedings | - |
| dc.citation.title | 2018 Purdue Conference Proceedings | - |
| dc.citation.startPage | 1 | - |
| dc.citation.endPage | 10 | - |
| dc.type.rims | ART | - |
| dc.type.docType | Proceeding | - |
| dc.description.journalClass | 1 | - |
| dc.description.isOpenAccess | Y | - |
| dc.description.journalRegisteredClass | other | - |
| dc.identifier.url | https://docs.lib.purdue.edu/cgi/viewcontent.cgi?article=2928&context=iracc | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1366
COPYRIGHT © 2024 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.