Effect of ventilation on indoor particle and CO2 concentration in public transport buses
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Woo, Seong eun | - |
dc.contributor.author | Park, Jun seok | - |
dc.contributor.author | Bang, Seung woo | - |
dc.contributor.author | Yun, Namseok | - |
dc.date.accessioned | 2022-07-11T15:45:22Z | - |
dc.date.available | 2022-07-11T15:45:22Z | - |
dc.date.created | 2021-05-14 | - |
dc.date.issued | 2018-07 | - |
dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/149669 | - |
dc.description.abstract | The purpose of this study was to quantify the levels of indoor particles and CO2 according to ventilation methods of public transport buses. The measurements were conducted in twelve routes in 2 different lines, intercity and interstate. From the results, when ventilation system is operated indoor CO2 concentration is reduced while PM concentration is increased, especially for PM2. These results indicate that the ventilation system in public transport is not enough to control particulate matters. | - |
dc.language | 영어 | - |
dc.language.iso | en | - |
dc.publisher | ISIAQ | - |
dc.title | Effect of ventilation on indoor particle and CO2 concentration in public transport buses | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Park, Jun seok | - |
dc.identifier.scopusid | 2-s2.0-85105626128 | - |
dc.identifier.bibliographicCitation | INDOOR AIR 2018, 15th Conference of the International Society of Indoor Air Quality and Climate, pp.820 - 821 | - |
dc.relation.isPartOf | INDOOR AIR 2018, 15th Conference of the International Society of Indoor Air Quality and Climate | - |
dc.citation.title | INDOOR AIR 2018, 15th Conference of the International Society of Indoor Air Quality and Climate | - |
dc.citation.startPage | 820 | - |
dc.citation.endPage | 821 | - |
dc.type.rims | ART | - |
dc.type.docType | Proceeding | - |
dc.description.journalClass | 1 | - |
dc.description.isOpenAccess | N | - |
dc.description.journalRegisteredClass | scopus | - |
dc.subject.keywordAuthor | CO2 | - |
dc.subject.keywordAuthor | Indoor air quality | - |
dc.subject.keywordAuthor | Particles | - |
dc.subject.keywordAuthor | Public transport bus | - |
dc.subject.keywordAuthor | Ventilation systems | - |
dc.identifier.url | https://www.isiaq.org/ia_2018_proceedings_page.php | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1365
COPYRIGHT © 2021 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.