Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Long-Term Outcomes After Metal-on-Metal Total Hip Arthroplasty With a 28-mm Head: A 17-to 23-Year Follow-Up Study of a Previous Report

Authors
Moon, Jun-KiKim, YeesukHwang, Kyu-TaeYang, Jae-HyukOh, Young-HaKim, Young-Ho
Issue Date
Jul-2018
Publisher
CHURCHILL LIVINGSTONE INC MEDICAL PUBLISHERS
Keywords
metal-on-metal; small head; total hip arthroplasty; osteolysis; survivorship
Citation
JOURNAL OF ARTHROPLASTY, v.33, no.7, pp.2165 - 2172
Indexed
SCIE
SCOPUS
Journal Title
JOURNAL OF ARTHROPLASTY
Volume
33
Number
7
Start Page
2165
End Page
2172
URI
https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/149769
DOI
10.1016/j.arth.2018.02.089
ISSN
0883-5403
Abstract
Background Second-generation, metal-on-metal total hip arthroplasty (MoM THA) using a 28-mm head has shown favorable results compared with large head MoM THA. The purpose of this study is to evaluate the long-term outcomes of cementless primary MoM THA with a 28-mm head and the incidence of osteolysis using computed tomography. Methods A total of 92 patients (53 men and 39 women) who underwent primary cementless MoM THA (114 hips) with a 28-mm head were enrolled in this study. Their mean age was 46.2 years at the time of surgery. The mean follow-up duration was 20 years. The Harris hip score, presence of thigh or groin pain, radiographic results, presence of peri-implant osteolysis, histologic analysis, and Kaplan-Meier survival curves were evaluated. Results The mean preoperative Harris hip score of 50.5 improved to 85.1 at the final follow-up. Eight patients (8 hips) experienced groin pain, but none had thigh pain. Twelve revisions (6.2%) were performed including 10 hips for aseptic loosening with osteolysis and 2 hips for periprosthetic fracture around the stem. At 23 years, 91% of patients were free from revision of the acetabular component due to aseptic loosening and 90.1% were free from revision of both femoral and acetabular components due to any reason. Osteolysis was identified around the cup in 12 cases (10.5%) and around the stem in 7 cases (6.1%). Conclusion MoM THA with a 28-mm head showed a relatively low rate of aseptic implant loosening at a mean follow-up of 20 years.
Files in This Item
Go to Link
Appears in
Collections
서울 의과대학 > 서울 병리학교실 > 1. Journal Articles
서울 의과대학 > 서울 정형외과학교실 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Yang, Jae Hyuk photo

Yang, Jae Hyuk
서울 의과대학 (서울 정형외과학교실)
Read more

Altmetrics

Total Views & Downloads

BROWSE