Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

The influence of bone graft procedures on primary stability and bone change of implants placed in fresh extraction sockets

Full metadata record
DC Field Value Language
dc.contributor.author전상호-
dc.contributor.author박창주-
dc.contributor.author황숙현-
dc.contributor.author이윤기-
dc.contributor.authorZhou, Cong-
dc.contributor.author장현석-
dc.contributor.author류재준-
dc.date.accessioned2022-07-12T00:47:37Z-
dc.date.available2022-07-12T00:47:37Z-
dc.date.issued2018-04-
dc.identifier.issn2288-8101-
dc.identifier.issn2288-8586-
dc.identifier.urihttps://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/150224-
dc.description.abstractBackground: This study was to evaluate the effect of bone graft procedure on the primary stability of implants installed in fresh sockets and assess the vertical alteration of peri-implant bone radiographically. Methods: Twenty-three implants were inserted in 18 patients immediately after tooth extraction. The horizontal gap between the implant and bony walls of the extraction socket was grafted with xenografts. The implant stability before and after graft procedure was measured by Osstell Mentor as implant stability quotient before bone graft (ISQ bbg) and implant stability quotient after bone graft (ISQ abg). Peri-apical radiographs were taken to measure peri-implant bone change immediately after implant surgery and 12 months after implant placement. Data were analyzed by independent t test; the relationships between stability parameters (insertion torque value (ITV), ISQ abg, and ISQ bbg) and peri-implant bone changes were analyzed according to Pearson correlation coefficients. Results: The increase of ISQ in low primary stability group (LPSG) was 6.87 ± 3.62, which was significantly higher than the increase in high primary stability group (HPSG). A significant correlation between ITV and ISQ bbg (R = 0.606, P = 0.002) was found; however, age and peri-implant bone change were not found significantly related to implant stability parameters. It was presented that there were no significant peri-implant bone changes at 1 year after bone graft surgery. Conclusions: Bone graft procedure is beneficial for increasing the primary stability of immediately placed implants, especially when the ISQ of implants is below 65 and that bone grafts have some effects on peri-implant bone maintenance.-
dc.format.extent6-
dc.language영어-
dc.language.isoENG-
dc.publisher대한악안면성형재건외과학회-
dc.titleThe influence of bone graft procedures on primary stability and bone change of implants placed in fresh extraction sockets-
dc.typeArticle-
dc.publisher.location대한민국-
dc.identifier.doi10.1186/s40902-018-0148-2-
dc.identifier.scopusid2-s2.0-85062822887-
dc.identifier.bibliographicCitationMaxillofacial Plastic and Reconstructive Surgery, v.40, no.1, pp 1 - 6-
dc.citation.titleMaxillofacial Plastic and Reconstructive Surgery-
dc.citation.volume40-
dc.citation.number1-
dc.citation.startPage1-
dc.citation.endPage6-
dc.identifier.kciidART002340947-
dc.description.isOpenAccessY-
dc.description.journalRegisteredClasskci-
dc.subject.keywordAuthorImmediate implant-
dc.subject.keywordAuthorBone graft-
dc.subject.keywordAuthorPrimary stability-
dc.subject.keywordAuthorPeri-implant bone change-
dc.identifier.urlhttps://jkamprs.springeropen.com/articles/10.1186/s40902-018-0148-2#citeas-
Files in This Item
Appears in
Collections
서울 의과대학 > 서울 치과학교실 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Park, Chang Joo photo

Park, Chang Joo
COLLEGE OF MEDICINE (DEPARTMENT OF DENTISTRY)
Read more

Altmetrics

Total Views & Downloads

BROWSE