Low-tube-voltage CT urography using low-concentration-iodine contrast media and iterative reconstruction: A multi-institutional randomized controlled trial for comparison with conventional CT urography

Full metadata record
DC Field Value Language
dc.contributor.authorKim, S.Y.-
dc.contributor.authorCho, J.Y.-
dc.contributor.authorLee, J.-
dc.contributor.authorHwang, S.I.-
dc.contributor.authorMoon, M.H.-
dc.contributor.authorLee, E.J.-
dc.contributor.authorHong, S.S.-
dc.contributor.authorKim, C.K.-
dc.contributor.authorKim, K.A.-
dc.contributor.authorPark, S.B.-
dc.contributor.authorSung, D.J.-
dc.contributor.authorKim, Yong Soo-
dc.contributor.authorKim, Y.M.-
dc.contributor.authorJung, S.I.-
dc.contributor.authorRha, S.E.-
dc.contributor.authorKim, D.W.-
dc.contributor.authorLee, H.-
dc.contributor.authorShim, Y.-
dc.contributor.authorHwang, I.-
dc.contributor.authorWoo, S.-
dc.contributor.authorChoi, H.J.-
dc.date.accessioned2022-07-12T19:59:06Z-
dc.date.available2022-07-12T19:59:06Z-
dc.date.created2021-05-13-
dc.date.issued2018-
dc.identifier.issn1229-6929-
dc.identifier.urihttps://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/150863-
dc.description.abstractObjective: To compare the image quality of low-tube-voltage and low-iodine-concentration-contrast-medium (LVLC) computed tomography urography (CTU) with iterative reconstruction (IR) with that of conventional CTU. Materials and Methods: This prospective, multi-institutional, randomized controlled trial was performed at 16 hospitals using CT scanners from various vendors. Patients were randomly assigned to the following groups: 1) the LVLC-CTU (80 kVp and 240 mgI/mL) with IR group and 2) the conventional CTU (120 kVp and 350 mgI/mL) with filtered-back projection group. The overall diagnostic acceptability, sharpness, and noise were assessed. Additionally, the mean attenuation, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and figure of merit (FOM) in the urinary tract were evaluated. Results: The study included 299 patients (LVLC-CTU group: 150 patients; conventional CTU group: 149 patients). The LVLC-CTU group had a significantly lower effective radiation dose (5.73 ± 4.04 vs. 8.43 ± 4.38 mSv) compared to the conventional CTU group. LVLC-CTU showed at least standard diagnostic acceptability (score ≥ 3), but it was non-inferior when compared to conventional CTU. The mean attenuation value, mean SNR, CNR, and FOM in all pre-defined segments of the urinary tract were significantly higher in the LVLC-CTU group than in the conventional CTU group. Conclusion: The diagnostic acceptability and quantitative image quality of LVLC-CTU with IR are not inferior to those of conventional CTU. Additionally, LVLC-CTU with IR is beneficial because both radiation exposure and total iodine load are reduced. © 2018 The Korean Society of Radiology.-
dc.language영어-
dc.language.isoen-
dc.publisherKorean Radiological Society-
dc.titleLow-tube-voltage CT urography using low-concentration-iodine contrast media and iterative reconstruction: A multi-institutional randomized controlled trial for comparison with conventional CT urography-
dc.typeArticle-
dc.contributor.affiliatedAuthorKim, Yong Soo-
dc.identifier.doi10.3348/kjr.2018.19.6.1119-
dc.identifier.scopusid2-s2.0-85055591641-
dc.identifier.wosid000447774500011-
dc.identifier.bibliographicCitationKorean Journal of Radiology, v.19, no.6, pp.1119 - 1129-
dc.relation.isPartOfKorean Journal of Radiology-
dc.citation.titleKorean Journal of Radiology-
dc.citation.volume19-
dc.citation.number6-
dc.citation.startPage1119-
dc.citation.endPage1129-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.identifier.kciidART002409790-
dc.description.journalClass1-
dc.description.isOpenAccessY-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.description.journalRegisteredClasskci-
dc.subject.keywordPlusiodinated contrast medium-
dc.subject.keywordPlusiodine-
dc.subject.keywordPlusiohexol-
dc.subject.keywordPluscontrast medium-
dc.subject.keywordPlusadult-
dc.subject.keywordPlusArticle-
dc.subject.keywordPlusbody mass-
dc.subject.keywordPluscomparative study-
dc.subject.keywordPluscomputer assisted tomography-
dc.subject.keywordPluscontrast enhancement-
dc.subject.keywordPluscontrast to noise ratio-
dc.subject.keywordPluscontrolled study-
dc.subject.keywordPlusdiagnostic test accuracy study-
dc.subject.keywordPlusfigure of merit-
dc.subject.keywordPlushuman-
dc.subject.keywordPlusimage quality-
dc.subject.keywordPlusimage reconstruction-
dc.subject.keywordPlusmajor clinical study-
dc.subject.keywordPlusmiddle aged-
dc.subject.keywordPlusosmolality-
dc.subject.keywordPlusprospective study-
dc.subject.keywordPlusradiation dose-
dc.subject.keywordPlusrandomized controlled trial-
dc.subject.keywordPlusrisk factor-
dc.subject.keywordPlussensitivity and specificity-
dc.subject.keywordPlussignal noise ratio-
dc.subject.keywordPlusurinary tract-
dc.subject.keywordPlusurography-
dc.subject.keywordPlusaged-
dc.subject.keywordPluschemistry-
dc.subject.keywordPluscomputer assisted diagnosis-
dc.subject.keywordPlusdevices-
dc.subject.keywordPlusdiagnostic imaging-
dc.subject.keywordPlusfemale-
dc.subject.keywordPlusmale-
dc.subject.keywordPlusprocedures-
dc.subject.keywordPlusurography-
dc.subject.keywordPlusx-ray computed tomography-
dc.subject.keywordPlusyoung adult-
dc.subject.keywordPlusAdult-
dc.subject.keywordPlusAged-
dc.subject.keywordPlusContrast Media-
dc.subject.keywordPlusFemale-
dc.subject.keywordPlusHumans-
dc.subject.keywordPlusImage Interpretation, Computer-Assisted-
dc.subject.keywordPlusIodine-
dc.subject.keywordPlusMale-
dc.subject.keywordPlusMiddle Aged-
dc.subject.keywordPlusProspective Studies-
dc.subject.keywordPlusSignal-To-Noise Ratio-
dc.subject.keywordPlusTomography, X-Ray Computed-
dc.subject.keywordPlusUrinary Tract-
dc.subject.keywordPlusUrography-
dc.subject.keywordPlusYoung Adult-
dc.subject.keywordAuthorComputed tomography-
dc.subject.keywordAuthorContrast media-
dc.subject.keywordAuthorDouble dose reduction-
dc.subject.keywordAuthorLow dose-
dc.subject.keywordAuthorUrography-
dc.identifier.urlhttps://www.kjronline.org/DOIx.php?id=10.3348/kjr.2018.19.6.1119-
Files in This Item
Appears in
Collections
서울 의과대학 > 서울 영상의학교실 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Yong Soo photo

Kim, Yong Soo
서울 의과대학 (DEPARTMENT OF RADIOLOGY)
Read more

Altmetrics

Total Views & Downloads

BROWSE