Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Optical Coherence Tomography Protocols for Screening of Hydroxychloroquine Retinopathy in Asian Patients

Full metadata record
DC Field Value Language
dc.contributor.authorAhn, Seong Joon-
dc.contributor.authorJoung, Jooyoung-
dc.contributor.authorLim, Han Woong-
dc.contributor.authorLee, Byung Ro-
dc.date.accessioned2022-07-12T20:44:17Z-
dc.date.available2022-07-12T20:44:17Z-
dc.date.issued2017-12-
dc.identifier.issn0002-9394-
dc.identifier.issn1879-1891-
dc.identifier.urihttps://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/151063-
dc.description.abstractPurpose To investigate the distribution of outer retinal changes in hydroxychloroquine (HCQ) retinopathy and explore optical coherence tomography (OCT) protocols to maximize the sensitivity of HCQ retinopathy detection in Asian patients. Design Diagnostic validity assessment. Methods Setting: Institutional. Patient Population: Forty-eight eyes (24 patients) with HCQ retinopathy underwent 6-mm horizontal and vertical line scans and 6 × 6-mm2 volume scans using spectral-domain OCT (SD-OCT), and 9-mm line scans and 6 × 6-mm2 and 12 × 9-mm2 volume scans using swept-source OCT (SS-OCT). Observation Procedures: Distances from the fovea to the defective photoreceptors were measured in the temporal, nasal, superior, and inferior directions from line scan OCT images. The sensitivity of retinopathy detection, indicated by photoreceptor defects, was compared among protocols. Main Outcome Measures: Detection of photoreceptor defects and distances from the fovea to the defects. Results The average minimum distance from the fovea to an area of photoreceptor defects was 1.84 ± 1.26 mm (mean ± standard deviation). The distances were greater than 3 mm horizontally and vertically in 15 (31.3%) and 17 (35.4%) eyes with HCQ retinopathy, respectively, and only wide-field line or volume scans could detect defects in the eyes. The 9-mm line scans detected HCQ retinopathy significantly better than 6-mm scans (P < .001); the sensitivity of the wide volume scan was significantly greater than the standard volume scan (P = .001). The 12 × 9-mm2 volume scan detected retinopathy with the greatest sensitivity (100%). Conclusions Our study recommends a wide-field OCT scan to screen Asian patients taking HCQ medications.-
dc.format.extent8-
dc.language영어-
dc.language.isoENG-
dc.publisherElsevier BV-
dc.titleOptical Coherence Tomography Protocols for Screening of Hydroxychloroquine Retinopathy in Asian Patients-
dc.typeArticle-
dc.publisher.location미국-
dc.identifier.doi10.1016/j.ajo.2017.09.025-
dc.identifier.scopusid2-s2.0-85031720069-
dc.identifier.wosid000417776400002-
dc.identifier.bibliographicCitationAmerican Journal of Ophthalmology, v.184, pp 11 - 18-
dc.citation.titleAmerican Journal of Ophthalmology-
dc.citation.volume184-
dc.citation.startPage11-
dc.citation.endPage18-
dc.type.docTypeArticle-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClasssci-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaOphthalmology-
dc.relation.journalWebOfScienceCategoryOphthalmology-
dc.subject.keywordPlusRECOMMENDATIONS-
dc.subject.keywordPlusCHLOROQUINE-
dc.subject.keywordPlusPROGRESSION-
dc.subject.keywordPlusTOXICITY-
dc.subject.keywordPlusTHERAPY-
dc.identifier.urlhttps://www.sciencedirect.com/science/article/pii/S0002939417304099?via%3Dihub-
Files in This Item
Go to Link
Appears in
Collections
서울 의과대학 > 서울 안과학교실 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Ahn, Seong Joon photo

Ahn, Seong Joon
서울 의과대학 (DEPARTMENT OF OPHTHALMOLOGY)
Read more

Altmetrics

Total Views & Downloads

BROWSE