Cited 0 time in
자외선 수처리기 적용을 통한 직접식증발냉각기 토출공기의 공기질 개선효과
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | 김원준 | - |
| dc.contributor.author | 박준영 | - |
| dc.contributor.author | 정재원 | - |
| dc.date.accessioned | 2022-07-12T23:45:36Z | - |
| dc.date.available | 2022-07-12T23:45:36Z | - |
| dc.date.created | 2021-05-14 | - |
| dc.date.issued | 2017-11 | - |
| dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/151142 | - |
| dc.description.abstract | The direct evaporative cooler operates by recirculating the water to reduce the amount of water required to operate the system. However, microbial contamination accumulates when water is recirculated. Such microbial contamination causes air quality degradation in the process air and may cause respiratory disease of the occupant. This study confirmed the relationship between air pollution and water quality of recirculated water used in a direct evaporative cooler. In the first experiment, bacterial contamination of the process air in the direct evaporative cooler was confirmed. In the second experiment, it was confirmed that air quality was improved when recirculated water treated with ultraviolet reactor was used in direct evaporative cooler. However, in botu experiments, it was confirmed that the air pollution of process air increased as the duration of operation increased. | - |
| dc.language | 한국어 | - |
| dc.language.iso | ko | - |
| dc.publisher | 대한설비공학회 | - |
| dc.title | 자외선 수처리기 적용을 통한 직접식증발냉각기 토출공기의 공기질 개선효과 | - |
| dc.title.alternative | Air Quality Improvement of Outlet Air by Direct Evaporative Cooler by Applying Ultraviolet Water Treatment System | - |
| dc.type | Article | - |
| dc.contributor.affiliatedAuthor | 정재원 | - |
| dc.identifier.bibliographicCitation | 대한설비공학회 2017년도 동계학술발표대회 논문집, pp.307 - 310 | - |
| dc.relation.isPartOf | 대한설비공학회 2017년도 동계학술발표대회 논문집 | - |
| dc.citation.title | 대한설비공학회 2017년도 동계학술발표대회 논문집 | - |
| dc.citation.startPage | 307 | - |
| dc.citation.endPage | 310 | - |
| dc.type.rims | ART | - |
| dc.type.docType | Proceeding | - |
| dc.description.journalClass | 2 | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | other | - |
| dc.subject.keywordAuthor | Direct evaporative cooler | - |
| dc.subject.keywordAuthor | Indoor air quality | - |
| dc.subject.keywordAuthor | Microbial contaminant | - |
| dc.subject.keywordAuthor | Ultraviolet reactor | - |
| dc.subject.keywordAuthor | 직접식 증발냉각기 | - |
| dc.subject.keywordAuthor | 실내공기질 | - |
| dc.subject.keywordAuthor | 미생물 오염 | - |
| dc.subject.keywordAuthor | 자외선 수처리 장치 | - |
| dc.identifier.url | https://www.dbpia.co.kr/journal/articleDetail?nodeId=NODE07284124 | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1366
COPYRIGHT © 2024 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.