Cited 0 time in
액체식 제습시스템이 적용된 전외기 공조시스템의 공기질 개선효과
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | 박준영 | - |
| dc.contributor.author | 임한솔 | - |
| dc.contributor.author | 조민석 | - |
| dc.contributor.author | 정재원 | - |
| dc.date.accessioned | 2022-07-12T23:45:58Z | - |
| dc.date.available | 2022-07-12T23:45:58Z | - |
| dc.date.created | 2021-05-14 | - |
| dc.date.issued | 2017-11 | - |
| dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/151148 | - |
| dc.description.abstract | The main purpose of this research is to evaluate the ability enhancement potential of a liquid desiccant (LD) system operation to remove microorganism particles. To verify the removal performance of microorganism particles, the experiment was conducted to modify the cases where the process air passed or bypassed the LD unit. Bacteria and fungi were considered for the measurement of the microorganism particles, with a minimum fan flow rate (800 m3/h). To verify the accuracy of the experiment, a duct system and an LD system were sealed with ducttape to prevent air leakage. Experimental results were obtained with a bio-contaminant sampler using a tryptic soy agar(TSA) and a potato dextrose agar(PDA). The measuring points were situated at a same distance from the liquid desiccant system inlet and outlet duct. The results show that the LD system has the ability to remove microorganism contaminants. The bacteria removal efficiencies were 77.5% and 81.3% for the sampling process air of 200 and 500 L, respectively, while the fungi removal efficiencies were 38.8% and 44.4% for 200 and 500 L, respectively, of sampling process air. | - |
| dc.language | 한국어 | - |
| dc.language.iso | ko | - |
| dc.publisher | 한국건축친환경설비학회 | - |
| dc.title | 액체식 제습시스템이 적용된 전외기 공조시스템의 공기질 개선효과 | - |
| dc.title.alternative | Air quality enhancement potential in a liquid desiccant assisted 100% outdoor air system | - |
| dc.type | Article | - |
| dc.contributor.affiliatedAuthor | 정재원 | - |
| dc.identifier.bibliographicCitation | 한국건축친환경설비학회 추계학술발표대회 논문집, pp.141 - 142 | - |
| dc.relation.isPartOf | 한국건축친환경설비학회 추계학술발표대회 논문집 | - |
| dc.citation.title | 한국건축친환경설비학회 추계학술발표대회 논문집 | - |
| dc.citation.startPage | 141 | - |
| dc.citation.endPage | 142 | - |
| dc.type.rims | ART | - |
| dc.type.docType | Proceeding | - |
| dc.description.journalClass | 3 | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | other | - |
| dc.subject.keywordAuthor | LD-IDEOCA | - |
| dc.subject.keywordAuthor | Liquid desiccant | - |
| dc.subject.keywordAuthor | Evaporative cooling system | - |
| dc.subject.keywordAuthor | Air quality | - |
| dc.subject.keywordAuthor | 제습증발냉각시스템 | - |
| dc.subject.keywordAuthor | 액체식 제습시스템 | - |
| dc.subject.keywordAuthor | 증발냉각 시스템 | - |
| dc.subject.keywordAuthor | 공기질 | - |
| dc.identifier.url | https://www.auric.or.kr/user/rdoc/DocRdoc.aspx?returnVal=RD_R&dn=355290#.YSbt599t-Uk | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1366
COPYRIGHT © 2024 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.