Cited 0 time in
플러쉬아웃에 따른 폼알데하이드 농도 저감 효과에 관한 연구
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | 박상인 | - |
| dc.contributor.author | 박준석 | - |
| dc.date.accessioned | 2022-07-12T23:47:20Z | - |
| dc.date.available | 2022-07-12T23:47:20Z | - |
| dc.date.created | 2021-05-14 | - |
| dc.date.issued | 2017-11 | - |
| dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/151172 | - |
| dc.description.abstract | This study measured the changes of HCHO concentrations in residential buildings before and after flush-out. The measured buildings are the pre-occupancy stage after completion of indoor finishing work. According to the guide for flush-out provided in based on the standards of health-friendly housing construction, outdoor air of 400m³ per unit floor area flows into the buildings. The buildings were set at three different flush-out condtions, for the confirm the effects of flush-out on lowering indoor HCHO concentrations in newly built buildings; one is no flush-out, the second is changes of the days of flush-out. The flush-out house and the new mechanical ventilation system for apartment were used at the rate of 0.5 times per hour for 14 days, while the flushout-only prototype ran 1.0 times per hour. The results of field measurement are described the below. | - |
| dc.language | 한국어 | - |
| dc.language.iso | ko | - |
| dc.publisher | 한국생활환경학회 | - |
| dc.title | 플러쉬아웃에 따른 폼알데하이드 농도 저감 효과에 관한 연구 | - |
| dc.title.alternative | Changes of Formaldehyde concentrations using Flush-Out in residential buildings | - |
| dc.type | Article | - |
| dc.contributor.affiliatedAuthor | 박준석 | - |
| dc.identifier.bibliographicCitation | 2017년도 한국생활환경학회 추계 학술대회 , pp.55 - 56 | - |
| dc.relation.isPartOf | 2017년도 한국생활환경학회 추계 학술대회 | - |
| dc.citation.title | 2017년도 한국생활환경학회 추계 학술대회 | - |
| dc.citation.startPage | 55 | - |
| dc.citation.endPage | 56 | - |
| dc.type.rims | ART | - |
| dc.type.docType | Proceeding | - |
| dc.description.journalClass | 3 | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | other | - |
| dc.subject.keywordAuthor | Flush-Out | - |
| dc.subject.keywordAuthor | Residential building | - |
| dc.subject.keywordAuthor | HCHO(Formaldehyde) | - |
| dc.subject.keywordAuthor | Indoor Air Quality | - |
| dc.identifier.url | https://www.wincfree.re.kr/Sub/PostView.aspx?mm=3&ss=1&pid=844&gid=0&cpage=12 | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1366
COPYRIGHT © 2024 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.