Evaluation of Screening US-detected Breast Masses by Combined Use of Elastography and Color Doppler US with B-Mode US in Women with Dense Breasts: A Multicenter Prospective Study
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Lee, Su Hyun | - |
dc.contributor.author | Chung, Jin | - |
dc.contributor.author | Choi, Hye Young | - |
dc.contributor.author | Choi, Seon Hyeong | - |
dc.contributor.author | Ryu, Eun Bi | - |
dc.contributor.author | Ko, Kyung Hee | - |
dc.contributor.author | Koo, Hye Ryoung | - |
dc.contributor.author | Park, Jeong Seon | - |
dc.contributor.author | Yi, Ann | - |
dc.contributor.author | Youk, Ji Hyun | - |
dc.contributor.author | Son, Eun Ju | - |
dc.contributor.author | Chu, A. Jung | - |
dc.contributor.author | Chang, Jung Min | - |
dc.contributor.author | Cho, Nariya | - |
dc.contributor.author | Jang, Myoung-jin | - |
dc.contributor.author | Kook, Shin Ho | - |
dc.contributor.author | Cha, Eun Suk | - |
dc.contributor.author | Moon, Woo Kyung | - |
dc.date.accessioned | 2022-07-12T23:51:49Z | - |
dc.date.available | 2022-07-12T23:51:49Z | - |
dc.date.created | 2021-05-12 | - |
dc.date.issued | 2017-11 | - |
dc.identifier.issn | 0033-8419 | - |
dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/151238 | - |
dc.description.abstract | Purpose To investigate the value of the combined use of elastography and color Doppler ultrasonography (US) with B-mode US for evaluation of screening US–detected breast masses in women with dense breasts. Materials and Methods This prospective, multicenter study included asymptomatic women with dense breasts who were referred for screening US between November 2013 and December 2014. Eligible women had a newly detected breast mass at conventional B-mode US screening, for which elastography and color Doppler US were performed. The following outcome measures were compared between B-mode US and the combination of B-mode US, elastography, and color Doppler US: area under the receiver operating characteristic curve (AUC), sensitivity, specificity, positive predictive value (PPV), and the number of false-positive findings at screening US. Results Among 1021 breast masses (mean size, 1.0 cm; range, 0.3–3.0 cm) in 1021 women (median age, 45 years), 68 were malignant (56 invasive). Addition of elastography and color Doppler US to B-mode US increased the AUC from 0.87 (95% confidence interval [CI]: 0.82, 0.91) to 0.96 (95% CI: 0.95, 0.98; P < .001); specificity from 27.0% (95% CI: 24.2%, 29.9%) to 76.4% (95% CI: 73.6%, 79.1%; P < .001) without loss in sensitivity (95% CI: −1.5%, 1.5%; P > .999); and PPV from 8.9% (95% CI: 7.0%, 11.2%) to 23.2% (95% CI: 18.5%, 28.5%; P < .001), while avoiding 67.7% (471 of 696) of unnecessary biopsies for nonmalignant lesions. Conclusion Addition of elastography and color Doppler US to B-mode US can increase the PPV of screening US in women with dense breasts while reducing the number of false-positive findings without missing cancers. | - |
dc.language | 영어 | - |
dc.language.iso | en | - |
dc.publisher | RADIOLOGICAL SOC NORTH AMERICA | - |
dc.title | Evaluation of Screening US-detected Breast Masses by Combined Use of Elastography and Color Doppler US with B-Mode US in Women with Dense Breasts: A Multicenter Prospective Study | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Park, Jeong Seon | - |
dc.identifier.doi | 10.1148/radiol.2017162424 | - |
dc.identifier.scopusid | 2-s2.0-85032179381 | - |
dc.identifier.wosid | 000413472000033 | - |
dc.identifier.bibliographicCitation | RADIOLOGY, v.285, no.2, pp.660 - 669 | - |
dc.relation.isPartOf | RADIOLOGY | - |
dc.citation.title | RADIOLOGY | - |
dc.citation.volume | 285 | - |
dc.citation.number | 2 | - |
dc.citation.startPage | 660 | - |
dc.citation.endPage | 669 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.description.journalClass | 1 | - |
dc.description.isOpenAccess | Y | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Radiology, Nuclear Medicine & Medical Imaging | - |
dc.relation.journalWebOfScienceCategory | Radiology, Nuclear Medicine & Medical Imaging | - |
dc.subject.keywordPlus | SHEAR-WAVE ELASTOGRAPHY | - |
dc.subject.keywordPlus | CLINICAL-APPLICATION | - |
dc.subject.keywordPlus | CANCER | - |
dc.subject.keywordPlus | MAMMOGRAPHY | - |
dc.subject.keywordPlus | PERFORMANCE | - |
dc.subject.keywordPlus | ULTRASOUND | - |
dc.subject.keywordPlus | BENIGN | - |
dc.subject.keywordPlus | MRI | - |
dc.subject.keywordPlus | GUIDELINES | - |
dc.subject.keywordPlus | BENEFITS | - |
dc.identifier.url | https://pubs.rsna.org/doi/10.1148/radiol.2017162424 | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1365
COPYRIGHT © 2021 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.