Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

A baseline drift detrending technique for fast scan cyclic voltammetry

Full metadata record
DC Field Value Language
dc.contributor.authorDeWaele, Mark-
dc.contributor.authorOh, Yoonbae-
dc.contributor.authorPark, Cheonho-
dc.contributor.authorKang, Yu Min-
dc.contributor.authorShin, Hojin-
dc.contributor.authorBlaha, Charles D.-
dc.contributor.authorBennet, Kevin E.-
dc.contributor.authorKim, In Young-
dc.contributor.authorLee, Kendall H.-
dc.contributor.authorJang, Dong Pyo-
dc.date.accessioned2022-07-13T04:23:48Z-
dc.date.available2022-07-13T04:23:48Z-
dc.date.issued2017-11-
dc.identifier.issn0003-2654-
dc.identifier.issn1364-5528-
dc.identifier.urihttps://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/151373-
dc.description.abstractFast scan cyclic voltammetry (FSCV) has been commonly used to measure extracellular neurotransmitter concentrations in the brain. Due to the unstable nature of the background currents inherent in FSCV measurements, analysis of FSCV data is limited to very short amounts of time using traditional background subtraction. In this paper, we propose the use of a zero-phase high pass filter (HPF) as the means to remove the background drift. Instead of the traditional method of low pass filtering across voltammograms to increase the signal to noise ratio, a HPF with a low cutoff frequency was applied to the temporal dataset at each voltage point to remove the background drift. As a result, the HPF utilizing cutoff frequencies between 0.001 Hz and 0.01 Hz could be effectively used to a set of FSCV data for removing the drifting patterns while preserving the temporal kinetics of the phasic dopamine response recorded in vivo. In addition, compared to a drift removal method using principal component analysis, this was found to be significantly more effective in reducing the drift (unpaired t-test p < 0.0001, t = 10.88) when applied to data collected from Tris buffer over 24 hours although a drift removal method using principal component analysis also showed the effective background drift reduction. The HPF was also applied to 5 hours of FSCV in vivo data. Electrically evoked dopamine peaks, observed in the nucleus accumbens, were clearly visible even without background subtraction. This technique provides a new, simple, and yet robust, approach to analyse FSCV data with an unstable background.-
dc.format.extent5-
dc.language영어-
dc.language.isoENG-
dc.publisherRoyal Society of Chemistry-
dc.titleA baseline drift detrending technique for fast scan cyclic voltammetry-
dc.typeArticle-
dc.publisher.location영국-
dc.identifier.doi10.1039/c7an01465a-
dc.identifier.scopusid2-s2.0-85033390073-
dc.identifier.wosid000414485800016-
dc.identifier.bibliographicCitationAnalyst, v.142, no.22, pp 4317 - 4321-
dc.citation.titleAnalyst-
dc.citation.volume142-
dc.citation.number22-
dc.citation.startPage4317-
dc.citation.endPage4321-
dc.type.docTypeArticle-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClasssci-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaChemistry-
dc.relation.journalWebOfScienceCategoryChemistry, Analytical-
dc.subject.keywordPlusBACKGROUND SUBTRACTION-
dc.subject.keywordPlusWAVE-FORM-
dc.subject.keywordPlusDOPAMINE-
dc.subject.keywordPlusMICROELECTRODES-
dc.subject.keywordPlusBRAIN-
dc.identifier.urlhttps://pubs.rsc.org/en/content/articlelanding/2017/AN/C7AN01465A-
Files in This Item
Appears in
Collections
서울 의과대학 > 서울 의공학교실 > 1. Journal Articles
서울 의생명공학전문대학원 > ETC > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, In Young photo

Kim, In Young
서울 의과대학 (DEPARTMENT OF BIOMEDICAL ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE