Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Comparison of EMG signals recorded by surface electrodes on endotracheal tube and thyroid cartilage during monitored thyroidectomy

Full metadata record
DC Field Value Language
dc.contributor.authorChiang, Feng-Yu-
dc.contributor.authorLu, I-Cheng-
dc.contributor.authorChang, Pi-Ying-
dc.contributor.authorDionigi, Gianlorenzo-
dc.contributor.authorRandolph, Gregory W.-
dc.contributor.authorSun, Hui-
dc.contributor.authorLee, Kang-Dae-
dc.contributor.authorTae, Kyung-
dc.contributor.authorJi, Yong Bae-
dc.contributor.authorKim, Sung Won-
dc.contributor.authorLee, Hyoung Shin-
dc.contributor.authorWu, Che-Wei-
dc.date.accessioned2022-07-13T11:26:19Z-
dc.date.available2022-07-13T11:26:19Z-
dc.date.created2021-05-11-
dc.date.issued2017-10-
dc.identifier.issn1607-551X-
dc.identifier.urihttps://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/151557-
dc.description.abstractA variety of electromyography (EMG) recording methods were reported during intraoperative neural monitoring (IONM) of recurrent laryngeal nerve (RLN) in thyroid surgery. This study compared two surface recording methods that were obtained by electrodes on endotracheal tube (ET) and thyroid cartilage (TC). This study analyzed 205 RLNs at risk in 110 patients undergoing monitored thyroidectomy. Each patient was intubated with an EMG ET during general anesthesia. A pair of single needle electrode was inserted obliquely into the TC lamina on each side. Standard IONM procedure was routinely followed, and EMG signals recorded by the ET and TC electrodes at each step were compared. In all nerves, evoked laryngeal EMG signals were reliably recorded by the ET and TC electrodes, and showed the same typical waveform and latency. The EMG signals recorded by the TC electrodes showed significantly higher amplitudes and stability compared to those by the ET electrodes. Both recording methods accurately detected 7 partial loss of signal (LOS) and 2 complete LOS events caused by traction stress, but only the ET electrodes falsely detected 3 LOS events caused by ET displacement during surgical manipulation. Two patients with true complete LOS experienced temporary RLN palsy postoperatively. Neither permanent RLN palsy, nor complications from ET or TC electrodes were encountered in this study. Both electrodes are effective and reliable for recording laryngeal EMG signals during monitored thyroidectomy. Compared to ET electrodes, TC electrodes obtain higher and more stable EMG signals as well as fewer false EMG results during IONM.-
dc.language영어-
dc.language.isoen-
dc.publisherELSEVIER TAIWAN-
dc.titleComparison of EMG signals recorded by surface electrodes on endotracheal tube and thyroid cartilage during monitored thyroidectomy-
dc.typeArticle-
dc.contributor.affiliatedAuthorTae, Kyung-
dc.contributor.affiliatedAuthorJi, Yong Bae-
dc.identifier.doi10.1016/j.kjms.2017.06.014-
dc.identifier.scopusid2-s2.0-85025127494-
dc.identifier.wosid000414702100004-
dc.identifier.bibliographicCitationKAOHSIUNG JOURNAL OF MEDICAL SCIENCES, v.33, no.10, pp.503 - 509-
dc.relation.isPartOfKAOHSIUNG JOURNAL OF MEDICAL SCIENCES-
dc.citation.titleKAOHSIUNG JOURNAL OF MEDICAL SCIENCES-
dc.citation.volume33-
dc.citation.number10-
dc.citation.startPage503-
dc.citation.endPage509-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.description.isOpenAccessY-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaResearch & Experimental Medicine-
dc.relation.journalWebOfScienceCategoryMedicine, Research & Experimental-
dc.subject.keywordPlusRECURRENT LARYNGEAL NERVE-
dc.subject.keywordPlusSURGERY-
dc.subject.keywordPlusINJURY-
dc.subject.keywordPlusPITFALLS-
dc.subject.keywordAuthorElectromyography recording-
dc.subject.keywordAuthorIntraoperative neural monitoring-
dc.subject.keywordAuthorRecurrent laryngeal nerve-
dc.subject.keywordAuthorVocal cord paralysis-
dc.subject.keywordAuthorThyroid surgery-
dc.identifier.urlhttps://onlinelibrary.wiley.com/doi/full/10.1016/j.kjms.2017.06.014-
Files in This Item
Appears in
Collections
서울 의과대학 > 서울 이비인후과학교실 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Ji, Yong Bae photo

Ji, Yong Bae
COLLEGE OF MEDICINE (DEPARTMENT OF OTOLARYNGOLOGY)
Read more

Altmetrics

Total Views & Downloads

BROWSE