Cited 0 time in
Experimental study on airtightness test methods in large buildings; proposal of averaging pressure difference method
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Lee, Dong-Seok | - |
| dc.contributor.author | Jeong, Jae-Weon | - |
| dc.contributor.author | Jo, Jun-Hun | - |
| dc.date.accessioned | 2022-07-13T11:35:20Z | - |
| dc.date.available | 2022-07-13T11:35:20Z | - |
| dc.date.issued | 2017-09 | - |
| dc.identifier.issn | 0360-1323 | - |
| dc.identifier.issn | 1873-684X | - |
| dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/151679 | - |
| dc.description.abstract | Airtightness measurement standards using the fan pressurization method are widely used for measuring residential units such as detached houses and apartment units. The measurement of airtightness for small buildings can be readily conducted through existing fan pressurization methods. However, it can be difficult to achieve accurate measurement results for large buildings, as the height and volume of the buildings are considerably increased. This paper empirically investigates factors that are to be considered in regard to airflow rate (Q) and pressure difference (Delta P), which are measurement values required for deriving more accurate airtightness values for large buildings. The specifications of the standards ISO 9972, EN 13829, ASTM E779, JIS A 2201, ATTMA TS 1, and CAN/CGSB 149.15 relating to Q. and Delta P are compared. Test conditions with respect to Q and Delta P are discussed for large building airtightness measurements. In measuring airtightness, a method is proposed in which the pressure difference at each floor of the building is measured and an average pressure difference value is used. Experiments were conducted on two multi-story office buildings using the method based on measuring pressure difference according to existing standards in tandem with the proposed pressure difference measurement method. The results of the experimental study show that the vertical pressure distribution across the overall building envelope can be significantly different when a building is pressurized. The airtightness values may also be different according to the measurement methods. This paper demonstrates how important it is to derive accurate Delta P values in measuring large building airtightness. | - |
| dc.format.extent | 11 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | Pergamon Press Ltd. | - |
| dc.title | Experimental study on airtightness test methods in large buildings; proposal of averaging pressure difference method | - |
| dc.type | Article | - |
| dc.publisher.location | 영국 | - |
| dc.identifier.doi | 10.1016/j.buildenv.2017.06.003 | - |
| dc.identifier.scopusid | 2-s2.0-85020272862 | - |
| dc.identifier.wosid | 000407184400006 | - |
| dc.identifier.bibliographicCitation | Building and Environment, v.122, pp 61 - 71 | - |
| dc.citation.title | Building and Environment | - |
| dc.citation.volume | 122 | - |
| dc.citation.startPage | 61 | - |
| dc.citation.endPage | 71 | - |
| dc.type.docType | Article | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.relation.journalResearchArea | Construction & Building Technology | - |
| dc.relation.journalResearchArea | Engineering | - |
| dc.relation.journalWebOfScienceCategory | Construction & Building Technology | - |
| dc.relation.journalWebOfScienceCategory | Engineering, Environmental | - |
| dc.relation.journalWebOfScienceCategory | Engineering, Civil | - |
| dc.subject.keywordPlus | STACK PRESSURE | - |
| dc.subject.keywordPlus | AIR | - |
| dc.subject.keywordAuthor | Airtightness | - |
| dc.subject.keywordAuthor | Large building | - |
| dc.subject.keywordAuthor | Pressurization test | - |
| dc.subject.keywordAuthor | Pressure difference | - |
| dc.subject.keywordAuthor | Standard | - |
| dc.subject.keywordAuthor | Field test | - |
| dc.identifier.url | https://www.sciencedirect.com/science/article/pii/S0360132317302305?via%3Dihub | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1366
COPYRIGHT © 2024 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.