Cited 0 time in
Status of the Electromagnetic Calorimeter Trigger system at the Belle II experiment
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Kim, Sunghyun | - |
| dc.contributor.author | Lee, Insoo | - |
| dc.contributor.author | Unno, Yuji | - |
| dc.contributor.author | Cheon, Byunggu | - |
| dc.date.accessioned | 2022-07-13T12:02:45Z | - |
| dc.date.available | 2022-07-13T12:02:45Z | - |
| dc.date.issued | 2017-09 | - |
| dc.identifier.issn | 1748-0221 | - |
| dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/151703 | - |
| dc.description.abstract | The Belle II experiment at the SuperKEKB collider in Japan has been under the construction toward a physics run in 2018 with an ultimate target of 40 times higher instantaneous luminosity than the KEKB collider. The main physics motivation is to search for the New Physics from heavy quark/lepton flavor decays. In order to select an event of interest efficiently under much higher luminosity and beam background environment than the KEKB, we have upgraded the Electromagnetic Calorimeter (ECL) hardware trigger system. It would be realized by the improvement of ECL trigger logic based on two main triggers, the total energy and the number of clusters, with an FPGA-based flexible architecture and a high speed serial link for the data transfer. We report the current status of hardware, firmware, and software that has been achieved so far. The overall scheme of the system will be presented as well. | - |
| dc.format.extent | 7 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | Institute of Physics | - |
| dc.title | Status of the Electromagnetic Calorimeter Trigger system at the Belle II experiment | - |
| dc.type | Article | - |
| dc.publisher.location | 영국 | - |
| dc.identifier.doi | 10.1088/1748-0221/12/09/C09004 | - |
| dc.identifier.scopusid | 2-s2.0-85030978964 | - |
| dc.identifier.wosid | 000409521500004 | - |
| dc.identifier.bibliographicCitation | Journal of Instrumentation, v.12, pp 1 - 7 | - |
| dc.citation.title | Journal of Instrumentation | - |
| dc.citation.volume | 12 | - |
| dc.citation.startPage | 1 | - |
| dc.citation.endPage | 7 | - |
| dc.type.docType | Article; Proceedings Paper | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.relation.journalResearchArea | Instruments & Instrumentation | - |
| dc.relation.journalWebOfScienceCategory | Instruments & Instrumentation | - |
| dc.subject.keywordAuthor | Trigger detectors | - |
| dc.subject.keywordAuthor | Calorimeters | - |
| dc.identifier.url | https://iopscience.iop.org/article/10.1088/1748-0221/12/09/C09004 | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1366
COPYRIGHT © 2024 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.
