액체식 제습시스템의 운전 방식에 따른 에너지 소비량 분석

Full metadata record
DC Field Value Language
dc.contributor.author조민석-
dc.contributor.author정재원-
dc.date.accessioned2022-07-13T16:05:23Z-
dc.date.available2022-07-13T16:05:23Z-
dc.date.created2021-05-13-
dc.date.issued2017-08-
dc.identifier.issn1976-6483-
dc.identifier.urihttps://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/151814-
dc.description.abstractThe objective of this paper is to investigate the applicability of a suggestion operation method applied to an liquid desiccant system (LD). The LD system which is divided into an absorber and a regenerator needs heating and cooling sources for appropriate dehumidification performance. To reduce the energy consumption of the heating and cooling sources in the LD, the suggestion operation method unlike conventional operation method which operates absorber and regenerator simultaneously was to control the operation of the absorber continuously and the regenerator as on and off. the simulation of the energy consumption was conducted to estimate the energy consumption of the LD operation with the proposed method using a commercial engineering equation solver (EES). The suggestion operation method was applied to an liquid desiccant and evaporative cooling-assisted 100% outdoor air system (LD- IDECOAS). As a result, the suggestion operation method showed 30% and 33% reduction in the load of heating and cooling source compared to the conventional operation method in LD-IDECOAS.-
dc.language한국어-
dc.language.isoko-
dc.publisher한국건축친환경설비학회-
dc.title액체식 제습시스템의 운전 방식에 따른 에너지 소비량 분석-
dc.title.alternativeEnergy Consumption of an Liquid Desiccant System depanding on Operation Method-
dc.typeArticle-
dc.contributor.affiliatedAuthor정재원-
dc.identifier.bibliographicCitation한국건축친환경설비학회 논문집, v.11, no.4, pp.283 - 294-
dc.relation.isPartOf한국건축친환경설비학회 논문집-
dc.citation.title한국건축친환경설비학회 논문집-
dc.citation.volume11-
dc.citation.number4-
dc.citation.startPage283-
dc.citation.endPage294-
dc.type.rimsART-
dc.identifier.kciidART002252492-
dc.description.journalClass2-
dc.description.isOpenAccessY-
dc.description.journalRegisteredClasskci-
dc.subject.keywordAuthorLiquid desiccant-
dc.subject.keywordAuthorLD-IDECOAS-
dc.subject.keywordAuthorEnergy consuption-
dc.subject.keywordAuthorEvaporative cooling system-
dc.subject.keywordAuthorOperation method-
dc.subject.keywordAuthor액체식 제습시스템-
dc.subject.keywordAuthor액체식 제습증발냉각기반 전외기 공조시스템-
dc.subject.keywordAuthor에너지소비-
dc.subject.keywordAuthor증발냉각 시스템-
dc.subject.keywordAuthor운전방법-
dc.identifier.urlhttps://www.dbpia.co.kr/pdf/pdfView.do?nodeId=NODE07266176&mark=0&useDate=&bookmarkCnt=0&ipRange=N&accessgl=Y&language=ko_KR-
Files in This Item
Appears in
Collections
서울 공과대학 > 서울 건축공학부 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Jeong, Jae Weon photo

Jeong, Jae Weon
COLLEGE OF ENGINEERING (SCHOOL OF ARCHITECTURAL ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE