Evaluation of image quality for stent image with different dilution ratio of contrast agent in self-production vessel model on angiographic X-ray computed tomography (CT)

Full metadata record
DC Field Value Language
dc.contributor.authorChoi, Hye Ran-
dc.contributor.authorChoi, Won Ho-
dc.contributor.authorLee, Seung Chan-
dc.contributor.authorHa, Yun Kyung-
dc.contributor.authorKang, Seong Hyeon-
dc.contributor.authorKim, Dae Ho-
dc.contributor.authorLee, Youngjin-
dc.date.accessioned2022-07-13T19:58:30Z-
dc.date.available2022-07-13T19:58:30Z-
dc.date.created2021-05-11-
dc.date.issued2017-08-
dc.identifier.issn0030-4026-
dc.identifier.urihttps://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/151921-
dc.description.abstractNowadays, the interest and the number of examination of cerebral angiography and interventional procedure have been significantly increasing. In stent procedure on patients, the important point is to check especially whether the position of stent is complete. Also, the dilution ratio of contrast agent and normal saline (N/S) causes affect the quality of image. Thus, the purpose of this study was to find optimized dilution ratio of contrast agent for acquiring the high quality image with various diameters of self-production vessel model in AAPM head phantom. To evaluate the quality of image, signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were used as a factor of quantitative measurement, and Likert scale was used as a factor of qualitative measurement. According to the results, we can acquire excellent result for 1:4 (contrast agent: N/S), 1:5, and 1:5 dilution ratios using 2, 3, and 5 mm vessel diameters, respectively. In addition, quantitative measurement and qualitative measurement came up with same tendency. In conclusion, our results demonstrated that the 1:4 and 1:5 dilution ratio of contrast agent had outstanding results in 2, 3, and 5 mm diameters of vessel model in phantom.-
dc.language영어-
dc.language.isoen-
dc.publisherELSEVIER GMBH-
dc.titleEvaluation of image quality for stent image with different dilution ratio of contrast agent in self-production vessel model on angiographic X-ray computed tomography (CT)-
dc.typeArticle-
dc.contributor.affiliatedAuthorKim, Dae Ho-
dc.identifier.doi10.1016/j.ijleo.2017.06.068-
dc.identifier.scopusid2-s2.0-85021379200-
dc.identifier.wosid000407401700023-
dc.identifier.bibliographicCitationOPTIK, v.143, pp.180 - 187-
dc.relation.isPartOfOPTIK-
dc.citation.titleOPTIK-
dc.citation.volume143-
dc.citation.startPage180-
dc.citation.endPage187-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaOptics-
dc.relation.journalWebOfScienceCategoryOptics-
dc.subject.keywordAuthorAngiography and interventional radiography-
dc.subject.keywordAuthorComputed tomography (CT)-
dc.subject.keywordAuthorX-ray photon imaging-
dc.subject.keywordAuthorStent image-
dc.subject.keywordAuthorDilution ratio of contrast agent-
dc.identifier.urlhttps://www.sciencedirect.com/science/article/pii/S0030402617307374?via%3Dihub-
Files in This Item
Go to Link
Appears in
Collections
서울 의과대학 > 서울 정신건강의학교실 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Dae ho photo

Kim, Dae ho
COLLEGE OF MEDICINE (DEPARTMENT OF PSYCHIATRY)
Read more

Altmetrics

Total Views & Downloads

BROWSE