Novel Technique to Overcome the Nonavailability of a Long Needle 9-0 Polypropylene Suture for Sutured Scleral Fixation of the Posterior Chamber Intraocular Lens Using a Single Fisherman's Knot

Full metadata record
DC Field Value Language
dc.contributor.authorShin, Yong Un-
dc.contributor.authorSeong, Mincheol-
dc.contributor.authorCho, Hee Yoon-
dc.contributor.authorKang, Min Ho-
dc.date.accessioned2022-07-14T01:46:20Z-
dc.date.available2022-07-14T01:46:20Z-
dc.date.created2021-05-11-
dc.date.issued2017-07-
dc.identifier.issn2090-004X-
dc.identifier.urihttps://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/152069-
dc.description.abstractPurpose: To describe a method to overcome the nonavailability of a long needle 9-0 polypropylene suture for sutured scleral fixation of the posterior chamber intraocular lens (PC-IOL) using a single fisherman's knot (SFK). Methods: First, a 10-0 polypropylene suture was passed from the sclera to the ciliary sulcus using a long needle. A 9-0 suture was tied to the unpassed portion of the 10-0 suture with an SFK. We pulled the 10-0 suture to pass the SFK through the sclera, and then we cut the knot and removed the 10-0 suture. IOL fixation with 9-0 sutures used the conventional techniques used for sutured scleral-fixated IOL. Preoperative and postoperative visual acuity, corneal astigmatism, and endothelial cell count and intraoperative/postoperative complications were evaluated. Results: An SFK joining the two sutures was passed through the sclera without breakage or slippage. A total of 35 eyes from 35 patients who underwent sutured scleral fixation of the IOL. An intraoperative complication (minor intraocular hemorrhage) was recorded in four cases. Knot exposure, IOL dislocation, subluxation, and retinal detachment were not observed. Conclusions: The SFK offers the opportunity to use 9-0 sutures for the long-term safety and may not require the surgeon to learn any new technique.-
dc.language영어-
dc.language.isoen-
dc.publisherHINDAWI LTD-
dc.titleNovel Technique to Overcome the Nonavailability of a Long Needle 9-0 Polypropylene Suture for Sutured Scleral Fixation of the Posterior Chamber Intraocular Lens Using a Single Fisherman's Knot-
dc.typeArticle-
dc.contributor.affiliatedAuthorShin, Yong Un-
dc.contributor.affiliatedAuthorSeong, Mincheol-
dc.contributor.affiliatedAuthorCho, Hee Yoon-
dc.contributor.affiliatedAuthorKang, Min Ho-
dc.identifier.doi10.1155/2017/2683415-
dc.identifier.scopusid2-s2.0-85042794358-
dc.identifier.wosid000407818600001-
dc.identifier.bibliographicCitationJOURNAL OF OPHTHALMOLOGY, v.2017, pp.1 - 5-
dc.relation.isPartOfJOURNAL OF OPHTHALMOLOGY-
dc.citation.titleJOURNAL OF OPHTHALMOLOGY-
dc.citation.volume2017-
dc.citation.startPage1-
dc.citation.endPage5-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.description.isOpenAccessY-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaResearch & Experimental Medicine-
dc.relation.journalResearchAreaOphthalmology-
dc.relation.journalWebOfScienceCategoryMedicine, Research & Experimental-
dc.relation.journalWebOfScienceCategoryOphthalmology-
dc.subject.keywordPlusCOMPLICATIONS-
dc.subject.keywordPlusIMPLANTATION-
dc.subject.keywordPlusEYES-
dc.identifier.urlhttps://www.hindawi.com/journals/joph/2017/2683415/-
Files in This Item
Appears in
Collections
서울 의과대학 > 서울 안과학교실 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kang, Min Ho photo

Kang, Min Ho
COLLEGE OF MEDICINE (DEPARTMENT OF OPHTHALMOLOGY)
Read more

Altmetrics

Total Views & Downloads

BROWSE