Cited 0 time in
공동주택에서의 기계환기설비 사용현황 및 유지관리
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | 박준석 | - |
| dc.date.accessioned | 2022-07-14T01:49:40Z | - |
| dc.date.available | 2022-07-14T01:49:40Z | - |
| dc.date.created | 2021-05-14 | - |
| dc.date.issued | 2017-06 | - |
| dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/152104 | - |
| dc.description.abstract | Abstract The purpose of this review was to evaluate occupants’ ventilation behaviour in homes with mechanical ventilation systems. Even though mechanical ventilation systems can reduce exposure to outdoor particles and also can improve IAQ more efficiently compared with natural ventilation, most of occupants did not use mechanical fans for ventilation. They cited elevated energy costs, difficulty of operation, unaware, and fan noise as the primary reasons for not using the mechanical ventilation fan. It was found from the previous researches that occupants prefer opening windows for ventilation and the ventilation system is operated only for a few days throughout a year. As the ventilation systems are intermittently operated in homes, a large amount of airborne particles may deposit to the supply duct surfaces when the mechanical fan is not operated, and therefore the deposited particles may resuspend into ventilation airflow when the mechanical fan is turn on. In aspects of maintenance, it is clear that airborne particle deposition in the ventilation systems affects occupant health and exposures. | - |
| dc.language | 한국어 | - |
| dc.language.iso | ko | - |
| dc.publisher | 대한설비공학회 | - |
| dc.title | 공동주택에서의 기계환기설비 사용현황 및 유지관리 | - |
| dc.title.alternative | Review: Maintenance and operation of Mechanical Ventilation systems in residential buildings | - |
| dc.type | Article | - |
| dc.contributor.affiliatedAuthor | 박준석 | - |
| dc.identifier.bibliographicCitation | 대한설비공학회 2017년도 하계학술발표대회 논문집, pp.257 - 260 | - |
| dc.relation.isPartOf | 대한설비공학회 2017년도 하계학술발표대회 논문집 | - |
| dc.citation.title | 대한설비공학회 2017년도 하계학술발표대회 논문집 | - |
| dc.citation.startPage | 257 | - |
| dc.citation.endPage | 260 | - |
| dc.type.rims | ART | - |
| dc.type.docType | Proceeding | - |
| dc.description.journalClass | 2 | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | other | - |
| dc.subject.keywordAuthor | Mechanical ventilation | - |
| dc.subject.keywordAuthor | Indoor Air Quality | - |
| dc.subject.keywordAuthor | Maintenance | - |
| dc.subject.keywordAuthor | Residential Building | - |
| dc.subject.keywordAuthor | 기계환기 | - |
| dc.subject.keywordAuthor | 실내공기질 | - |
| dc.subject.keywordAuthor | 유지관리 | - |
| dc.subject.keywordAuthor | 주택 | - |
| dc.identifier.url | https://www.dbpia.co.kr/journal/articleDetail?nodeId=NODE07224163 | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1366
COPYRIGHT © 2024 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.
