자동혈압계 성능평가를 위한 인체혈압 시뮬레이터 개발
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 도일 | - |
dc.contributor.author | 임현균 | - |
dc.contributor.author | 안봉영 | - |
dc.contributor.author | 지영준 | - |
dc.contributor.author | 이종실 | - |
dc.contributor.author | 오재훈 | - |
dc.date.accessioned | 2022-07-14T01:54:52Z | - |
dc.date.available | 2022-07-14T01:54:52Z | - |
dc.date.created | 2021-05-13 | - |
dc.date.issued | 2017-06 | - |
dc.identifier.issn | 1229-0807 | - |
dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/152182 | - |
dc.description.abstract | Blood pressure is one of the important vital signs for monitoring the medical condition of a patient. Automated NIBP(non-invasive blood pressure) monitoring devices calculate systolic and diastolic blood pressures from the oscillation in cuff pressure caused by a pulsation of an artery. To validate the NIBP devices, we developed a simulator to supply the oscillometric waveforms obtained from human subjects. The simulator provided pressure pulses to device-under-test and device readings were compared to the auscultatory references. Fully automated simulation system including OCR(optical character recognition) were developed and used for NIBP monitoring devices. The validation results using the simulator agreed well with previous clinical validation. More validation studies using the standardized oscillometric waveforms would be required for the replacement of clinical trials to validate a new automated NIBP monitoring device. | - |
dc.language | 한국어 | - |
dc.language.iso | ko | - |
dc.publisher | 대한의용생체공학회 | - |
dc.title | 자동혈압계 성능평가를 위한 인체혈압 시뮬레이터 개발 | - |
dc.title.alternative | A Simulator for the Validation of Non-invasive Blood Pressure(NIBP) Monitoring Devices | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | 오재훈 | - |
dc.identifier.doi | 10.9718/JBER.2017.38.3.111 | - |
dc.identifier.bibliographicCitation | 의공학회지, v.38, no.3, pp.111 - 115 | - |
dc.relation.isPartOf | 의공학회지 | - |
dc.citation.title | 의공학회지 | - |
dc.citation.volume | 38 | - |
dc.citation.number | 3 | - |
dc.citation.startPage | 111 | - |
dc.citation.endPage | 115 | - |
dc.type.rims | ART | - |
dc.identifier.kciid | ART002233260 | - |
dc.description.journalClass | 2 | - |
dc.description.isOpenAccess | N | - |
dc.description.journalRegisteredClass | kci | - |
dc.subject.keywordAuthor | Non-invasive blood pressure(NIBP) | - |
dc.subject.keywordAuthor | Simulator | - |
dc.subject.keywordAuthor | Oscillometric waveform | - |
dc.subject.keywordAuthor | Clinical validation | - |
dc.subject.keywordAuthor | Pressure Pulse | - |
dc.identifier.url | http://koreascience.or.kr/article/JAKO201720861273578.page | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1365
COPYRIGHT © 2021 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.