Cited 0 time in
Reduction Effect of Indoor Air Pollutants by Flush-out in New-built Apartment Buildings
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Kim, Joohan | - |
| dc.contributor.author | Park, Jun seok | - |
| dc.date.accessioned | 2022-07-14T07:22:49Z | - |
| dc.date.available | 2022-07-14T07:22:49Z | - |
| dc.date.created | 2021-05-14 | - |
| dc.date.issued | 2017-04 | - |
| dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/152490 | - |
| dc.description.abstract | As the Korean society pays more attention to residents' health, sick building syndrome has recently become a main topic. Along with it, studies have also been actively conducted on sick building syndrome, which can arise when apartment buildings are newly constructed. As an preventive measure, the government enacted Health-friendly building code. This measure requires that a construction company flush-out indoor air pollutants, which cause sick building syndrome, with mechanical ventilation system or large fans after interior work and before occupants move in. However, the criteria for flush-out only include are established only for mandatory air volume and recommended temperature and humidity, not specify a way to execute flush-out. In this respect, the present study carried out a flush-out for a newly-built apartment building before residents moved in and examined its reduction effect on indoor air pollutants. | - |
| dc.language | 영어 | - |
| dc.language.iso | en | - |
| dc.publisher | 대한건축학회 | - |
| dc.title | Reduction Effect of Indoor Air Pollutants by Flush-out in New-built Apartment Buildings | - |
| dc.type | Article | - |
| dc.contributor.affiliatedAuthor | Park, Jun seok | - |
| dc.identifier.bibliographicCitation | 2017 동아시아 건축, 도시 국제컨퍼런스, pp.248 - 252 | - |
| dc.relation.isPartOf | 2017 동아시아 건축, 도시 국제컨퍼런스 | - |
| dc.citation.title | 2017 동아시아 건축, 도시 국제컨퍼런스 | - |
| dc.citation.startPage | 248 | - |
| dc.citation.endPage | 252 | - |
| dc.type.rims | ART | - |
| dc.type.docType | Proceeding | - |
| dc.description.journalClass | 3 | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | other | - |
| dc.subject.keywordAuthor | Flush-out | - |
| dc.subject.keywordAuthor | Residential building | - |
| dc.subject.keywordAuthor | Indoor Air Quality | - |
| dc.subject.keywordAuthor | Ventilation | - |
| dc.identifier.url | https://www.wincfree.re.kr/Sub/PostView.aspx?mm=3&ss=1&pid=850&gid=0&cpage=12 | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1366
COPYRIGHT © 2024 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.
