RF Heating Study of a New Medical Implant Lead for 1.5 T, 3 T, and 7 T MRI Systems

Full metadata record
DC Field Value Language
dc.contributor.authorDas, Rupam-
dc.contributor.authorYoo, Hyoung suk-
dc.date.accessioned2022-07-14T07:23:47Z-
dc.date.available2022-07-14T07:23:47Z-
dc.date.created2021-05-14-
dc.date.issued2017-04-
dc.identifier.issn0018-9375-
dc.identifier.urihttps://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/152510-
dc.description.abstractIn the presence of an electrically conducting medical lead, radio frequency (RF) coils in magnetic resonance imaging (MRI) systems may concentrate the RF energy and cause tissue heating near the lead. Here, we present a novel design for a medical lead to reduce this heating by introducing pins. A pin can be taught as an electrical short that connects the main lead to the surrounding tissues. Initially, detail analysis of our proposed design is carried out by using Ansoft HFSS. Then, peak 10 g specific absorption rate (SAR) in heart tissue, an indicator of heating, was calculated and compared for both conventional design and our proposed design. Remcom XFdtd software was used to calculate the peak SAR distribution in a realistic model of the human body. The model contained a medical lead that was exposed to RF magnetic fields at 64 (1.5 T), 128 (3 T), and 300 MHz (7 T) using a model of a magnetic resonance birdcage body coil. We demonstrate that our proposed design of adding pins to the medical lead can significantly reduce the heating from different MRI systems.-
dc.language영어-
dc.language.isoen-
dc.publisherIEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC-
dc.titleRF Heating Study of a New Medical Implant Lead for 1.5 T, 3 T, and 7 T MRI Systems-
dc.typeArticle-
dc.contributor.affiliatedAuthorYoo, Hyoung suk-
dc.identifier.doi10.1109/TEMC.2016.2614894-
dc.identifier.bibliographicCitationIEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, v.59, no.2, pp.360 - 366-
dc.relation.isPartOfIEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY-
dc.citation.titleIEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY-
dc.citation.volume59-
dc.citation.number2-
dc.citation.startPage360-
dc.citation.endPage366-
dc.type.rimsART-
dc.type.docType정기학술지(Article(Perspective Article포함))-
dc.description.journalClass1-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.subject.keywordAuthorElectromagnetic compatibility-
dc.subject.keywordAuthorheating-
dc.subject.keywordAuthorimplantable biomedical devices-
dc.subject.keywordAuthormagnetic resonance imaging (MRI)-
dc.subject.keywordAuthorSpecific absorption rate (SAR)-
dc.identifier.urlhttps://ieeexplore.ieee.org/document/7600437-
Files in This Item
Go to Link
Appears in
Collections
ETC > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Yoo, Hyoungsuk photo

Yoo, Hyoungsuk
COLLEGE OF ENGINEERING (서울 바이오메디컬공학전공)
Read more

Altmetrics

Total Views & Downloads

BROWSE