뿜칠피복 각형 강관의 내화성능 평가를 위한 실험적 연구
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | 옥치열 | - |
| dc.contributor.author | 김재준 | - |
| dc.date.accessioned | 2022-07-14T12:30:21Z | - |
| dc.date.available | 2022-07-14T12:30:21Z | - |
| dc.date.issued | 2017-03 | - |
| dc.identifier.issn | 1598-4095 | - |
| dc.identifier.issn | 2287-7401 | - |
| dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/152705 | - |
| dc.description.abstract | Structures of steel frame buildings getting vary depending on the development of construction technology. Fire-resistant steel beams and Columns accredited by accreditation bodies from the performance of various fire-resistant coating is applied to the current pillar method is most H-beams. H-beam has been proposed a non-load test specifications in the relevant regulations, its scope of accreditation to be granted without limitation of size H-beams from the performance of the test specification. However, in the case of the rectangular steel structure is to check its performance and to a separate one of the receive acknowledge and so take advantage of the cross-sectional shape factor in this study to test the performance of the fire-resistant structure proposed for standard test specimen. | - |
| dc.format.extent | 7 | - |
| dc.language | 한국어 | - |
| dc.language.iso | KOR | - |
| dc.publisher | 한국공간구조학회 | - |
| dc.title | 뿜칠피복 각형 강관의 내화성능 평가를 위한 실험적 연구 | - |
| dc.title.alternative | An Experimental Study on the Evaluation of the Fire-Resistance Performance of a Spray-Applied Rectangular Steel Structure | - |
| dc.type | Article | - |
| dc.publisher.location | 대한민국 | - |
| dc.identifier.doi | 10.9712/KASS.2017.17.1.041 | - |
| dc.identifier.bibliographicCitation | 한국공간구조학회지, v.17, no.1, pp 41 - 47 | - |
| dc.citation.title | 한국공간구조학회지 | - |
| dc.citation.volume | 17 | - |
| dc.citation.number | 1 | - |
| dc.citation.startPage | 41 | - |
| dc.citation.endPage | 47 | - |
| dc.identifier.kciid | ART002206151 | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | kci | - |
| dc.subject.keywordAuthor | Fire resistant structure | - |
| dc.subject.keywordAuthor | Fire protection | - |
| dc.subject.keywordAuthor | Sectional factor | - |
| dc.subject.keywordAuthor | Fireproof paint-coated structure | - |
| dc.identifier.url | http://journal.kasss.or.kr/journal/article.php?code=50847 | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1366
COPYRIGHT © 2024 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.