Cited 0 time in
하이브리드 변압기 회로 모델링을 적용한 전력계통연계형 태양광발전 시스템의 고조파 영향 분석
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | 오진택 | - |
| dc.contributor.author | 이재호 | - |
| dc.contributor.author | 고광철 | - |
| dc.date.accessioned | 2022-07-14T20:07:09Z | - |
| dc.date.available | 2022-07-14T20:07:09Z | - |
| dc.date.created | 2021-05-13 | - |
| dc.date.issued | 2017-01 | - |
| dc.identifier.issn | 1229-4691 | - |
| dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/153040 | - |
| dc.description.abstract | The hybrid transformer is developed for not only boosting voltage but also removing harmonic in 2009. So far researches for hybrid transformer have been done about study of only operation characteristic or analysis by using simulation of grid mainly. In this paper, we modeled the hybrid transformer and analyze its effect in real power grid. For verifying reduction of harmonic, we modeled the grid-connected photovoltaic generation system, which is typical eco-friendly generator, as a harmonic source. Hybrid transformer, a transformer with Zig-Zag winding, is used in analyzing the phase change between input and output voltage when the winding direction of the transformer is altered. Also, the harmonic content of source is analyzed depending on the existence of hybrid transformer. As a result, it can be seen that the hybrid transformer reduces the harmonic content by 9%. | - |
| dc.language | 한국어 | - |
| dc.language.iso | ko | - |
| dc.publisher | 한국조명.전기설비학회 | - |
| dc.title | 하이브리드 변압기 회로 모델링을 적용한 전력계통연계형 태양광발전 시스템의 고조파 영향 분석 | - |
| dc.title.alternative | Analysis of Harmonic Effect on Grid-connected Photovoltaic Generation System applying Hybrid Transformer Circuit Modeling | - |
| dc.type | Article | - |
| dc.contributor.affiliatedAuthor | 고광철 | - |
| dc.identifier.doi | 10.5207/JIEIE.2017.31.1.019 | - |
| dc.identifier.bibliographicCitation | 조명.전기설비학회논문지, v.31, no.1, pp.19 - 25 | - |
| dc.relation.isPartOf | 조명.전기설비학회논문지 | - |
| dc.citation.title | 조명.전기설비학회논문지 | - |
| dc.citation.volume | 31 | - |
| dc.citation.number | 1 | - |
| dc.citation.startPage | 19 | - |
| dc.citation.endPage | 25 | - |
| dc.type.rims | ART | - |
| dc.identifier.kciid | ART002192458 | - |
| dc.description.journalClass | 2 | - |
| dc.description.isOpenAccess | Y | - |
| dc.description.journalRegisteredClass | kci | - |
| dc.subject.keywordAuthor | Harmonics | - |
| dc.subject.keywordAuthor | Hybrid Transformer | - |
| dc.subject.keywordAuthor | Zig-Zag Windings | - |
| dc.identifier.url | https://www.dbpia.co.kr/journal/articleDetail?nodeId=NODE07098504&language=ko_KR&hasTopBanner=true | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1366
COPYRIGHT © 2024 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.