Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Electric probe diagnostics for measuring SOL parameters, wall and divertor fluxes in KSTAR

Full metadata record
DC Field Value Language
dc.contributor.authorKim, Heung-Su-
dc.contributor.authorBak, Jun-Gyo-
dc.contributor.authorBae, Min-Keun-
dc.contributor.authorChung, Kyu-Sun-
dc.contributor.authorHong, Suk-Ho-
dc.date.accessioned2022-07-15T04:18:58Z-
dc.date.available2022-07-15T04:18:58Z-
dc.date.created2021-05-12-
dc.date.issued2016-11-
dc.identifier.issn0920-3796-
dc.identifier.urihttps://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/153612-
dc.description.abstractSome components in electric probe diagnostics (EPDs) are improved in order to investigate characteristics of edge plasmas in the upstream scrape-off-layer (SOL) region and to measure wall and divertor fluxes during L-mode and H-mode plasma discharges in the Korea Superconducting Tokamak Advanced Research (KSTAR). From the upgrades in the EPDs, the measured error of the elapsed distance for the evaluation of the SOL profiles can be reduced up to 1% and the ion saturation current of up to 1.0A near an outer strike point (OSP) can be measured at the divertor region. In the SOL profile measurements during L-mode and inner wall limited plasma (B-T = 2.0T, I-p =0.4 MA), the e-folding lengths in the main SOL region lambda(Te) and lambda(ne) are evaluated as 3.5 cm and 2.1 cm, respectively. From particle flux measurement at the far SOL region during a diverted ELMy H-mode discharge (B-T = 1.8 T, I-p = 0.65 MA), peaked heat flux toward to outboard wall during ELM bursts is estimated up to similar to 20 k Wm(-2), which may be less than 1% of the peaked divertor heat flux expected for the neutral beam (NB) heating power P-NB of similar to 2.66 MW and stored energy W-TOT of similar to 0.38 MJ. In addition, the movement of the OSP during a diverted H-mode plasma (B-T = 2.4T, I-p = 0.5 MA) can be detected from the divertor probe measurement and peaked heat flux near the OSP is estimated as few MW m(-2) for P-NB = 3.0 MW, W-TOT = similar to 0.25 MJ. In this work, the technical details of the EPDs including its upgrades and some experimental results from EPD measurements are presented.-
dc.language영어-
dc.language.isoen-
dc.publisherELSEVIER SCIENCE SA-
dc.titleElectric probe diagnostics for measuring SOL parameters, wall and divertor fluxes in KSTAR-
dc.typeArticle-
dc.contributor.affiliatedAuthorChung, Kyu-Sun-
dc.identifier.doi10.1016/j.fusengdes.2016.01.070-
dc.identifier.scopusid2-s2.0-84957060352-
dc.identifier.wosid000382421900141-
dc.identifier.bibliographicCitationFUSION ENGINEERING AND DESIGN, v.109, pp.809 - 816-
dc.relation.isPartOfFUSION ENGINEERING AND DESIGN-
dc.citation.titleFUSION ENGINEERING AND DESIGN-
dc.citation.volume109-
dc.citation.startPage809-
dc.citation.endPage816-
dc.type.rimsART-
dc.type.docTypeArticle; Proceedings Paper-
dc.description.journalClass1-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaNuclear Science & Technology-
dc.relation.journalWebOfScienceCategoryNuclear Science & Technology-
dc.subject.keywordPlusTRANSMISSION FACTORS-
dc.subject.keywordPlusDISCHARGES-
dc.subject.keywordAuthorKSTAR-
dc.subject.keywordAuthorElectric probe diagnostics-
dc.subject.keywordAuthorSOL parameters-
dc.subject.keywordAuthorParticle and heat fluxes-
dc.identifier.urlhttps://www.sciencedirect.com/science/article/pii/S0920379616300709?via%3Dihub-
Files in This Item
Go to Link
Appears in
Collections
서울 공과대학 > 서울 전기공학전공 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Chung, Kyu Sun photo

Chung, Kyu Sun
서울 공과대학 (서울 전기공학전공)
Read more

Altmetrics

Total Views & Downloads

BROWSE