Cited 0 time in
히트펌프를 적용한 액체식 제습 시스템과 기존 액체식 제습 시스템의 에너지 소비 비교 분석
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | 신장훈 | - |
| dc.contributor.author | 이성준 | - |
| dc.contributor.author | 조상현 | - |
| dc.contributor.author | 정재원 | - |
| dc.date.accessioned | 2022-07-15T05:12:15Z | - |
| dc.date.available | 2022-07-15T05:12:15Z | - |
| dc.date.issued | 2016-10 | - |
| dc.identifier.issn | 2287-5786 | - |
| dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/153674 | - |
| dc.description.abstract | Vibrant researches on heat pump driven liquid desiccant (HPLD) system, which utilizes heating capacity and cooling capacity from condenser and evaporator respectively, have been conducted rapidly in recent years. The purpose of this paper is to assess the energy saving potential of a HPLD system compared with a conventional liquid desiccant (LD) system. Aqueous solution of LiCl was used in the LD system and R134a was used for the refrigerant in the heat pump. A simulation based on an empirical model of absorber was conducted, and total energy consumption in the proposed HPLD system were compared and analyzed with that of the conventional LD system. As a result, the proposed system showed better performance than the conventional liquid desiccant system in terms of energy saving. Moreover, HPLD is expeced to have a great advantage in the aspect of compactness from the replacement of the cooling and heating devices in the conventional LD system with a heat pump. | - |
| dc.format.extent | 2 | - |
| dc.language | 한국어 | - |
| dc.language.iso | KOR | - |
| dc.publisher | 대한건축학회 | - |
| dc.title | 히트펌프를 적용한 액체식 제습 시스템과 기존 액체식 제습 시스템의 에너지 소비 비교 분석 | - |
| dc.title.alternative | Energy Performance Comparison between Heat Pump-driven Liquid Desiccant System and Conventional Liquid Desiccant System | - |
| dc.type | Article | - |
| dc.publisher.location | 대한민국 | - |
| dc.identifier.bibliographicCitation | 2016 대한건축학회 추계학술발표대회논문집, v.36, no.2, pp 605 - 606 | - |
| dc.citation.title | 2016 대한건축학회 추계학술발표대회논문집 | - |
| dc.citation.volume | 36 | - |
| dc.citation.number | 2 | - |
| dc.citation.startPage | 605 | - |
| dc.citation.endPage | 606 | - |
| dc.type.docType | Proceeding | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | domestic | - |
| dc.subject.keywordAuthor | 히트펌프 운전 액체식 제습 시스템 | - |
| dc.subject.keywordAuthor | 하이브리드 액체식 제습 시스템 | - |
| dc.subject.keywordAuthor | 히트펌프 | - |
| dc.subject.keywordAuthor | 액체식 제습 시스템 | - |
| dc.subject.keywordAuthor | 에너지 소비 | - |
| dc.subject.keywordAuthor | 에너지 절약 | - |
| dc.subject.keywordAuthor | Heat pump driven liquid desiccant system | - |
| dc.subject.keywordAuthor | Hybrid liquid desiccant system | - |
| dc.subject.keywordAuthor | Heat pump | - |
| dc.subject.keywordAuthor | Liquid desiccant system | - |
| dc.subject.keywordAuthor | Energy performance | - |
| dc.subject.keywordAuthor | Energy saving | - |
| dc.identifier.url | https://www.dbpia.co.kr/journal/articleDetail?nodeId=NODE07156063 | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1366
COPYRIGHT © 2024 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.
