dc.description.abstractVibrant researches on heat pump driven liquid desiccant (HPLD) system, which utilizes heating capacity and cooling capacity from condenser and evaporator respectively, have been conducted rapidly in recent years. The purpose of this paper is to assess the energy saving potential of a HPLD system compared with a conventional liquid desiccant (LD) system. Aqueous solution of LiCl was used in the LD system and R134a was used for the refrigerant in the heat pump. A simulation based on an empirical model of absorber was conducted, and total energy consumption in the proposed HPLD system were compared and analyzed with that of the conventional LD system. As a result, the proposed system showed better performance than the conventional liquid desiccant system in terms of energy saving. Moreover, HPLD is expeced to have a great advantage in the aspect of compactness from the replacement of the cooling and heating devices in the conventional LD system with a heat pump.-
dc.format.extent2-
dc.language한국어-
dc.language.isoKOR-
dc.publisher대한건축학회-
dc.title히트펌프를 적용한 액체식 제습 시스템과 기존 액체식 제습 시스템의 에너지 소비 비교 분석-
dc.title.alternativeEnergy Performance Comparison between Heat Pump-driven Liquid Desiccant System and Conventional Liquid Desiccant System-
dc.typeArticle-
dc.publisher.location대한민국-
dc.identifier.bibliographicCitation2016 대한건축학회 추계학술발표대회논문집, v.36, no.2, pp 605 - 606-
dc.citation.title2016 대한건축학회 추계학술발표대회논문집-
dc.citation.volume36-
dc.citation.number2-
dc.citation.startPage605-
dc.citation.endPage606-
dc.type.docTypeProceeding-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassdomestic-
dc.subject.keywordAuthor히트펌프 운전 액체식 제습 시스템-
dc.subject.keywordAuthor하이브리드 액체식 제습 시스템-
dc.subject.keywordAuthor히트펌프-
dc.subject.keywordAuthor액체식 제습 시스템-
dc.subject.keywordAuthor에너지 소비-
dc.subject.keywordAuthor에너지 절약-
dc.subject.keywordAuthorHeat pump driven liquid desiccant system-
dc.subject.keywordAuthorHybrid liquid desiccant system-
dc.subject.keywordAuthorHeat pump-
dc.subject.keywordAuthorLiquid desiccant system-
dc.subject.keywordAuthorEnergy performance-
dc.subject.keywordAuthorEnergy saving-
dc.identifier.urlhttps://www.dbpia.co.kr/journal/articleDetail?nodeId=NODE07156063-
Files in This Item
Go to Link
Appears in
Collections
서울 공과대학 > 서울 건축공학부 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Jeong, Jae Weon photo

Jeong, Jae Weon
COLLEGE OF ENGINEERING (SCHOOL OF ARCHITECTURAL ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE