Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

A mechanical pencil lead-supported carbon nanotube/Au nanodendrite structure as an electrochemical sensor for As(III) detection

Full metadata record
DC Field Value Language
dc.contributor.authorDuy, Pham Khac-
dc.contributor.authorSohn, Jong-Ryeul-
dc.contributor.authorChung, Hoeil-
dc.date.accessioned2022-07-15T05:34:01Z-
dc.date.available2022-07-15T05:34:01Z-
dc.date.created2021-05-12-
dc.date.issued2016-10-
dc.identifier.issn0003-2654-
dc.identifier.urihttps://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/153831-
dc.description.abstractA mechanical pencil lead (MPL), an easily obtainable carbon-based material with a consistent size, was used as a frame to construct an MPL-supported carbon nanotube/Au nanodendrite (MPL-CNT/AuND) sensor through simple electrodeposition of Au onto the MPL in the presence of CNTs. A nanodendrite structure was adopted to ensure large numbers of active electrochemical sites because of its hierarchical structure with well-aligned terraces; the CNTs were used to firmly adhere the fabricated Au nanodendrites to the MPL surface to ensure ruggedness. The MPL-CNT/AuND structure was used to measure As3+ samples in a concentration range from 0.5 to 80 ppb using anodic stripping voltammetry (ASV). The variation in peak intensities was linear (R-2: 0.997), and the limit of detection (LOD) was 0.4 ppb. The average relative standard deviation (RSD) of the peak intensities from the voltammograms of each sample collected using three separately prepared MPL-CNT/AuNDs was 8.7%, thereby demonstrating good sensor-to-sensor reproducibility. Furthermore, when three As3+ samples prepared in tap water were measured, the accuracy was maintained without noticeable degradation and the response was steady up to 50-cycle measurements.-
dc.language영어-
dc.language.isoen-
dc.publisherROYAL SOC CHEMISTRY-
dc.titleA mechanical pencil lead-supported carbon nanotube/Au nanodendrite structure as an electrochemical sensor for As(III) detection-
dc.typeArticle-
dc.contributor.affiliatedAuthorChung, Hoeil-
dc.identifier.doi10.1039/c6an00803h-
dc.identifier.scopusid2-s2.0-84990038515-
dc.identifier.wosid000385152600026-
dc.identifier.bibliographicCitationANALYST, v.141, no.20, pp.5879 - 5885-
dc.relation.isPartOfANALYST-
dc.citation.titleANALYST-
dc.citation.volume141-
dc.citation.number20-
dc.citation.startPage5879-
dc.citation.endPage5885-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaChemistry-
dc.relation.journalWebOfScienceCategoryChemistry, Analytical-
dc.subject.keywordPlusANODIC-STRIPPING VOLTAMMETRY-
dc.subject.keywordPlusGRAPHITE-ELECTRODES-
dc.subject.keywordPlusGOLD NANORODS-
dc.subject.keywordPlusTRACE-METALS-
dc.subject.keywordPlusBIOSENSOR-
dc.identifier.urlhttps://pubs.rsc.org/en/content/articlelanding/2016/AN/C6AN00803H-
Files in This Item
Go to Link
Appears in
Collections
서울 자연과학대학 > 서울 화학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Chung, Hoeil photo

Chung, Hoeil
COLLEGE OF NATURAL SCIENCES (DEPARTMENT OF CHEMISTRY)
Read more

Altmetrics

Total Views & Downloads

BROWSE