Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Empirical model for predicting the dehumidification effectiveness of a liquid desiccant system

Full metadata record
DC Field Value Language
dc.contributor.authorPark, Joon-Young-
dc.contributor.authorYoon, Dong-Seop-
dc.contributor.authorLee, Sung-Joon-
dc.contributor.authorJeong, Jae-Weon-
dc.date.accessioned2022-07-15T12:21:03Z-
dc.date.available2022-07-15T12:21:03Z-
dc.date.created2021-05-12-
dc.date.issued2016-08-
dc.identifier.issn0378-7788-
dc.identifier.urihttps://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/154206-
dc.description.abstractThe main purpose of this research was to propose a practical correlation for predicting the dehumidification effectiveness of a liquid desiccant (LD) system. The experimental data were collected during the operation of a typical liquid desiccant dehumidification unit. A lithium chloride (LiCI) solution was.used as the liquid desiccant solution. The 2000 m3/h LD unit was installed in a real building, and the variation of the dehumidification effectiveness values was monitored under various operating conditions. The data were statistically analyzed by the response surface methodology (REM), and the impact of each system operation parameter on the dehumidification effectiveness was estimated quantitatively. Six operating parameters - the mass flow rate of process air, the mass flow rate of the desiccant solution, the dry-bulb temperature and the humidity ratio of the inlet air, and the inlet temperature and concentration of the desiccant solution - significantly affected the dehumidification performance of the LD unit. Consequently, a simplified linear equation model was derived as a function of the operation parameters that significantly impacted the dehumidification effectiveness. The proposed model was verified by comparison with existing models. (C) 2016 Elsevier B.V. All rights reserved.-
dc.language영어-
dc.language.isoen-
dc.publisherELSEVIER SCIENCE SA-
dc.titleEmpirical model for predicting the dehumidification effectiveness of a liquid desiccant system-
dc.typeArticle-
dc.contributor.affiliatedAuthorJeong, Jae-Weon-
dc.identifier.doi10.1016/j.enbuild.2016.05.050-
dc.identifier.scopusid2-s2.0-84974574239-
dc.identifier.wosid000381529300039-
dc.identifier.bibliographicCitationENERGY AND BUILDINGS, v.126, pp.447 - 454-
dc.relation.isPartOfENERGY AND BUILDINGS-
dc.citation.titleENERGY AND BUILDINGS-
dc.citation.volume126-
dc.citation.startPage447-
dc.citation.endPage454-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaConstruction & Building Technology-
dc.relation.journalResearchAreaEnergy & Fuels-
dc.relation.journalResearchAreaEngineering-
dc.relation.journalWebOfScienceCategoryConstruction & Building Technology-
dc.relation.journalWebOfScienceCategoryEnergy & Fuels-
dc.relation.journalWebOfScienceCategoryEngineering, Civil-
dc.subject.keywordPlusMASS-TRANSFER PERFORMANCE-
dc.subject.keywordPlusCOOLING SYSTEM-
dc.subject.keywordPlusPACKED-COLUMN-
dc.subject.keywordPlusAIR-
dc.subject.keywordAuthorLiquid desiccant-
dc.subject.keywordAuthorDehumidification effectiveness-
dc.subject.keywordAuthorAbsorber-
dc.subject.keywordAuthorDesiccant cooling-
dc.identifier.urlhttps://www.sciencedirect.com/science/article/pii/S0378778816304194?via%3Dihub-
Files in This Item
Go to Link
Appears in
Collections
서울 공과대학 > 서울 건축공학부 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Jeong, Jae Weon photo

Jeong, Jae Weon
COLLEGE OF ENGINEERING (SCHOOL OF ARCHITECTURAL ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE