Cited 0 time in
Use of Multiple Peptide-Based SERS Probes Binding to Different Epitopes on a Protein Biomarker To Improve Detection Sensitivity
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Shin, Kayeong | - |
| dc.contributor.author | Cho, Jun-Haeng | - |
| dc.contributor.author | Yoon, Moon-Young | - |
| dc.contributor.author | Chung, Hoeil | - |
| dc.date.accessioned | 2022-07-15T17:57:46Z | - |
| dc.date.available | 2022-07-15T17:57:46Z | - |
| dc.date.issued | 2016-04 | - |
| dc.identifier.issn | 0003-2700 | - |
| dc.identifier.issn | 1520-6882 | - |
| dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/154874 | - |
| dc.description.abstract | We propose an analytical strategy to improve the sensitivity for detecting a protein biomarker through signal multiplication by manipulating multiple peptide-based surface enhanced Raman scattering (SERS) probes to bind the biomarker. Protective antigen (PA) was used as an Anthrax biomarker in this study. For this purpose, five small peptides selective to various PA epitopes with different binding affinities were chosen and peptide conjugated Au nanoparticle (AuNP) SERS probes were individually prepared using each peptide. Initially, five different SERS probes were separately used to detect PA and the sensitivities were compared. Next, the possibility of enhancing sensitivity by employing multiple SERS probes was examined: Rather than applying the probes simultaneously, which would induce competitive binding, each probe was added sequentially and an optimal probe-addition sequence was determined to provide maximal sensitivity. Finally, PA samples at seven different concentrations were measured with the optimal sequence. The limit of detection (LOD) was 0.1 aM, and the enhancement was more effective at lower PA concentrations. The proposed scheme can be further applicable to detect other protein biomarkers to diagnose various diseases. | - |
| dc.format.extent | 6 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | American Chemical Society | - |
| dc.title | Use of Multiple Peptide-Based SERS Probes Binding to Different Epitopes on a Protein Biomarker To Improve Detection Sensitivity | - |
| dc.type | Article | - |
| dc.publisher.location | 미국 | - |
| dc.identifier.doi | 10.1021/acs.analchem.5b04873 | - |
| dc.identifier.scopusid | 2-s2.0-84963818684 | - |
| dc.identifier.wosid | 000373656300009 | - |
| dc.identifier.bibliographicCitation | Analytical Chemistry, v.88, no.7, pp 3465 - 3470 | - |
| dc.citation.title | Analytical Chemistry | - |
| dc.citation.volume | 88 | - |
| dc.citation.number | 7 | - |
| dc.citation.startPage | 3465 | - |
| dc.citation.endPage | 3470 | - |
| dc.type.docType | Article | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | sci | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.relation.journalResearchArea | Chemistry | - |
| dc.relation.journalWebOfScienceCategory | Chemistry, Analytical | - |
| dc.subject.keywordPlus | ENHANCED RAMAN-SCATTERING | - |
| dc.subject.keywordPlus | ANTHRAX-PROTECTIVE ANTIGEN | - |
| dc.subject.keywordPlus | PHAGE DISPLAY | - |
| dc.subject.keywordPlus | TOXIN | - |
| dc.subject.keywordPlus | NANOSTRUCTURES | - |
| dc.subject.keywordPlus | NANOPARTICLES | - |
| dc.subject.keywordPlus | RECOGNITION | - |
| dc.subject.keywordPlus | MONOLAYERS | - |
| dc.subject.keywordPlus | SURFACES | - |
| dc.subject.keywordPlus | COLLOIDS | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1366
COPYRIGHT © 2024 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.