False Loss of Resistance in Cervical Epidural Injection: The Loss of Resistance Technique Compared with the Epidrum Guidance in Locating Epidural Space.
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Lee, Jin Young | - |
dc.contributor.author | Lee, Sangmin M. | - |
dc.contributor.author | Sim, Woo Seog | - |
dc.contributor.author | Ahn, Hyun Joo | - |
dc.contributor.author | Park, Mi Hye | - |
dc.contributor.author | Lim, Hyun young | - |
dc.contributor.author | Lee, Soo Hee | - |
dc.contributor.author | Kim, Young Ri | - |
dc.contributor.author | Kim, Young Il | - |
dc.contributor.author | Bang, Yu Jeong | - |
dc.date.accessioned | 2022-07-15T18:06:08Z | - |
dc.date.available | 2022-07-15T18:06:08Z | - |
dc.date.created | 2021-05-13 | - |
dc.date.issued | 2016-03 | - |
dc.identifier.issn | 1533-3159 | - |
dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/154937 | - |
dc.description.abstract | Background: Epidural block failures can occur due to a misleading loss of resistance (LOR) signal. Objective: This study was designed to evaluate the false LOR rate and to determine whether the Epidrum, which is an LOR device for identifying the epidural space, improves the ability to find the epidural space during cervical epidural injection compared the LOR technique. Study Design: A randomized, single-blind trial. Setting: Single academic medical center. Methods: A total of 150 patients undergoing cervical interlaminar epidural injections at C7-T1 were randomized to receive either the LOR technique with a syringe (group C) or the Epidrum guidance (group E). Fluoroscopic images were used to confirm the accuracy of the needle placement within the epidural space. The rate of misleading epidural signals and adverse effects were recorded and analyzed. Results: The false LOR rate was 74.7% for group C, 62.7% for group E, and 68.7% overall. The incidence of false LOR was not significantly different between the 2 groups. Also, the success rate and the rate of true epidural signals were similar between the 2 groups. Limitations: The Epidrum cannot be used to confirm whether the needle has entered the vascular space without fluoroscopy. Conclusions: In this study, we did not find any difference in accuracy between the Epidrum and the LOR technique with a syringe for detecting the cervical epidural space. The overall higher false LOR rate suggests that the combined use of fluoroscopy and LOR technique with a syringe or the Epidrum is necessary to increase the rate of finding the true cervical epidural space. | - |
dc.language | 영어 | - |
dc.language.iso | en | - |
dc.publisher | AM SOC INTERVENTIONAL PAIN PHYSICIANS | - |
dc.title | False Loss of Resistance in Cervical Epidural Injection: The Loss of Resistance Technique Compared with the Epidrum Guidance in Locating Epidural Space. | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Lim, Hyun young | - |
dc.identifier.scopusid | 2-s2.0-84961634142 | - |
dc.identifier.wosid | 000377771100018 | - |
dc.identifier.bibliographicCitation | PAIN PHYSICIAN, v.19, no.3, pp.131 - 138 | - |
dc.relation.isPartOf | PAIN PHYSICIAN | - |
dc.citation.title | PAIN PHYSICIAN | - |
dc.citation.volume | 19 | - |
dc.citation.number | 3 | - |
dc.citation.startPage | 131 | - |
dc.citation.endPage | 138 | - |
dc.type.rims | ART | - |
dc.type.docType | 정기학술지(Article(Perspective Article포함)) | - |
dc.description.journalClass | 1 | - |
dc.description.isOpenAccess | N | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Anesthesiology | - |
dc.relation.journalResearchArea | Neurosciences & Neurology | - |
dc.relation.journalWebOfScienceCategory | Anesthesiology | - |
dc.relation.journalWebOfScienceCategory | Clinical Neurology | - |
dc.subject.keywordPlus | LIGAMENTUM-FLAVUM | - |
dc.subject.keywordPlus | IDENTIFY | - |
dc.subject.keywordPlus | SYRINGE | - |
dc.subject.keywordPlus | DEVICE | - |
dc.subject.keywordAuthor | Cervical epidural injection | - |
dc.subject.keywordAuthor | epidural space | - |
dc.subject.keywordAuthor | Epidrum | - |
dc.subject.keywordAuthor | false positive | - |
dc.subject.keywordAuthor | false negative | - |
dc.subject.keywordAuthor | loss of resistance | - |
dc.identifier.url | https://www.painphysicianjournal.com/current/abstracts?article=MjYwNQ%3D%3D&journal=95 | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1365
COPYRIGHT © 2021 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.