Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

The reference phantoms: voxel vs polygon

Full metadata record
DC Field Value Language
dc.contributor.authorKim, Chan Hyeong-
dc.contributor.authorYeom, Yeon-Soo-
dc.contributor.authorNguyen, Thang Tat-
dc.contributor.authorWang,Zhao Jun-
dc.contributor.authorKim, Han-Sung-
dc.contributor.authorHan, Min Cheol-
dc.contributor.authorLee, Jai-Ki-
dc.contributor.authorZankl, Maria Agnes-
dc.contributor.authorPetoussi-Henss, Nina-
dc.contributor.authorBaBolch, Wesley Emmettolch, W.E.-
dc.contributor.authorLee, Choonsik-
dc.contributor.authorChung, Beom Sun-
dc.date.accessioned2022-07-15T18:09:28Z-
dc.date.available2022-07-15T18:09:28Z-
dc.date.created2021-05-13-
dc.date.issued2016-03-
dc.identifier.issn0146-6453-
dc.identifier.urihttps://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/154988-
dc.description.abstractThe International Commission on Radiological Protection (ICRP) reference male and female adult phantoms, described in Publication 110, are voxel phantoms based on whole-body computed tomography scans of a male and a female patient, respectively. The voxel in-plane resolution and the slice thickness, of the order of a few millimetres, are insufficient for proper segmentation of smaller tissues such as the lens of the eye, the skin, and the walls of some organs. The calculated doses for these tissues therefore present some limitations, particularly for weakly penetrating radiation. Similarly, the Publication 110 phantoms cannot represent 8?40-?m-thick target regions in respiratory or alimentary tract organs. Separate stylised models have been used to represent these tissues for calculation of the ICRP reference dose coefficients (DCs). ICRP Committee 2 recently initiated a research project, the ultimate goal of which is to convert the Publication 110 phantoms to a high-quality polygon-mesh (PM) format, including all source and target regions, even those of the 8?40-?m-thick alimentary and respiratory tract organs. It is expected that the converted phantoms would lead to the same or very similar DCs as the Publication 110 reference phantoms for penetrating radiation and, at the same time, provide more accurate DCs for weakly penetrating radiation and small tissues. Additionally, the reference phantoms in the PM format would be easily deformable and, as such, could serve as a starting point to create phantoms of various postures for use, for example, in accidental dose calculations. This paper will discuss the current progress of the phantom conversion project and its significance for ICRP DC calculations.-
dc.language영어-
dc.language.isoen-
dc.publisherSAGE Publications Ltd-
dc.titleThe reference phantoms: voxel vs polygon-
dc.typeArticle-
dc.contributor.affiliatedAuthorKim, Chan Hyeong-
dc.identifier.doi10.1177/0146645315626036-
dc.identifier.scopusid2-s2.0-84966929687-
dc.identifier.bibliographicCitationAnnals of the ICRP, v.45, pp.188 - 201-
dc.relation.isPartOfAnnals of the ICRP-
dc.citation.titleAnnals of the ICRP-
dc.citation.volume45-
dc.citation.startPage188-
dc.citation.endPage201-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.description.isOpenAccessY-
dc.description.journalRegisteredClassscopus-
dc.subject.keywordPlusArticle-
dc.subject.keywordPlusbody regions-
dc.subject.keywordPluscontrolled study-
dc.subject.keywordPlusdosimetry-
dc.subject.keywordPlusintermethod comparison-
dc.subject.keywordPlusmathematical model-
dc.subject.keywordPlusradiation dose-
dc.subject.keywordPlusradiology phantom-
dc.subject.keywordPlusdevices-
dc.subject.keywordPlushuman-
dc.subject.keywordPlusimaging phantom-
dc.subject.keywordPlusinternational cooperation-
dc.subject.keywordPlusradiation monitoring-
dc.subject.keywordPlusradiation protection-
dc.subject.keywordPlusreference value-
dc.subject.keywordPlusx-ray computed tomography-
dc.subject.keywordPlusHumans-
dc.subject.keywordPlusInternational Agencies-
dc.subject.keywordPlusPhantoms, Imaging-
dc.subject.keywordPlusRadiation Monitoring-
dc.subject.keywordPlusRadiation Protection-
dc.subject.keywordPlusReference Values-
dc.subject.keywordPlusTomography, X-Ray Computed-
dc.subject.keywordAuthorEffective dose-
dc.subject.keywordAuthorPolygon mesh-
dc.subject.keywordAuthorReference phantom-
dc.subject.keywordAuthorVoxel-
dc.identifier.urlhttps://journals.sagepub.com/doi/10.1177/0146645315626036-
Files in This Item
Appears in
Collections
서울 공과대학 > 서울 원자력공학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Chan Hyeong photo

Kim, Chan Hyeong
COLLEGE OF ENGINEERING (DEPARTMENT OF NUCLEAR ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE