Cited 0 time in
적층된 에폭시 고체유전체와 도전성 파티클에 대한 Dry-Air의 연면방전특성
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | 임동영 | - |
| dc.contributor.author | 전종철 | - |
| dc.contributor.author | 배성우 | - |
| dc.contributor.author | 이광식 | - |
| dc.contributor.author | 박원주 | - |
| dc.date.accessioned | 2022-07-15T18:27:11Z | - |
| dc.date.available | 2022-07-15T18:27:11Z | - |
| dc.date.created | 2021-05-13 | - |
| dc.date.issued | 2016-02 | - |
| dc.identifier.issn | 1229-4691 | - |
| dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/155130 | - |
| dc.description.abstract | This paper presents the surface discharge characteristics in Dry-Air on laminated epoxy solid dielectrics and conductive particles in order to provide the valuable information for the insulation design of eco- friendly gas insulated switchgear. To improve insulation performance, the three types of the laminated epoxy solid dielectrics were proposed, and it was revealed that their surface discharge characteristics were similar to the bakelite dielectrics of same-laminated types. From the surface discharge characteristics of dry air, it was demonstrated that the effect of conductive particles on surface discharge voltage was dominant when there are this particles at the shortest electrode gap and that the degradation of insulation performance on the conductive particles was evident in epoxy than teflon. These phenomena were interpreted in terms of particle-triggered discharge mechanism and electric field of triple junction, respectively. | - |
| dc.language | 한국어 | - |
| dc.language.iso | ko | - |
| dc.publisher | 한국조명.전기설비학회 | - |
| dc.title | 적층된 에폭시 고체유전체와 도전성 파티클에 대한 Dry-Air의 연면방전특성 | - |
| dc.title.alternative | Surface Discharge Characteristics in Dry-Air on Laminated Epoxy Solid Dielectrics and Conductive Particle | - |
| dc.type | Article | - |
| dc.contributor.affiliatedAuthor | 배성우 | - |
| dc.identifier.doi | 10.5207/JIEIE.2016.30.2.093 | - |
| dc.identifier.bibliographicCitation | 조명.전기설비학회논문지, v.30, no.2, pp.93 - 101 | - |
| dc.relation.isPartOf | 조명.전기설비학회논문지 | - |
| dc.citation.title | 조명.전기설비학회논문지 | - |
| dc.citation.volume | 30 | - |
| dc.citation.number | 2 | - |
| dc.citation.startPage | 93 | - |
| dc.citation.endPage | 101 | - |
| dc.type.rims | ART | - |
| dc.identifier.kciid | ART002080149 | - |
| dc.description.journalClass | 2 | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | kci | - |
| dc.subject.keywordAuthor | Conductive particle | - |
| dc.subject.keywordAuthor | Dielectric polarization | - |
| dc.subject.keywordAuthor | Dry-air | - |
| dc.subject.keywordAuthor | Epoxy resin | - |
| dc.subject.keywordAuthor | Gas insulated switchgear | - |
| dc.subject.keywordAuthor | Surface discharge | - |
| dc.identifier.url | https://www.dbpia.co.kr/journal/articleDetail?nodeId=NODE06613213&language=ko_KR&hasTopBanner=true | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1366
COPYRIGHT © 2024 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.