Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Radiation Doses of Various CT Protocols: A Multicenter Longitudinal Observation Study

Authors
Jang, JinheeJung, Seung EunJeong, Woo KyoungLim, Yeon SooChoi, Joon-IlPark, Michael YongKim, Yong SooLee, Seung-KooChung, Jae-JoonEo, HongYong, Hwan SeokHwang, Sung Su
Issue Date
Feb-2016
Publisher
대한의학회
Keywords
Multidetector Computed Tomography; Radiation Dose; Radiology; Longitudinal Studies
Citation
Journal of Korean Medical Science, v.31, no.suppl1, pp S24 - S31
Indexed
SCI
SCIE
SCOPUS
KCI
Journal Title
Journal of Korean Medical Science
Volume
31
Number
suppl1
Start Page
S24
End Page
S31
URI
https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/155212
DOI
10.3346/jkms.2016.31.S1.S24
ISSN
1011-8934
1598-6357
Abstract
Emerging concerns regarding the hazard from medical radiation including CT examinations has been suggested. The purpose of this study was to observe the longitudinal changes of CT radiation doses of various CT protocols and to estimate the long-term efforts of supervising radiologists to reduce medical radiation. Radiation dose data from 11 representative CT protocols were collected from 12 hospitals. Attending radiologists had collected CT radiation dose data in two time points, 2007 and 2010. They collected the volume CT dose index (CTDIvol) of each phase, number of phases, dose length product (DLP) of each phase, and types of scanned CT machines. From the collected data, total DLP and effective dose (ED) were calculated. CTDIvol, total DLP, and ED of 2007 and 2010 were compared according to CT protocols, CT machine type, and hospital. During the three years, CTDI(vo)l had significantly decreased, except for dynamic CT of the liver. Total DLP and ED were significantly decreased in all 11 protocols. The decrement was more evident in newer CT scanners. However, there was substantial variability of changes of ED during the three years according to hospitals. Although there was variability according to protocols, machines, and hospital, CT radiation doses were decreased during the 3 years. This study showed the effects of decreased CT radiation dose by efforts of radiologists and medical society.
Files in This Item
Appears in
Collections
서울 의과대학 > 서울 영상의학교실 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Yong Soo photo

Kim, Yong Soo
서울 의과대학 (DEPARTMENT OF RADIOLOGY)
Read more

Altmetrics

Total Views & Downloads

BROWSE