Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

White Matter Change Revealed by Diffusion Tensor Imaging in Gliomas

Full metadata record
DC Field Value Language
dc.contributor.author원영일-
dc.contributor.authorChung, Chun Kee-
dc.contributor.authorKim, Chi Heon-
dc.contributor.authorPark, Chul-Kee-
dc.contributor.authorKoo, Bang-Bon-
dc.contributor.authorLee, Jong Min-
dc.contributor.authorJung, Hee-Won-
dc.date.accessioned2022-07-15T19:30:02Z-
dc.date.available2022-07-15T19:30:02Z-
dc.date.issued2016-00-
dc.identifier.issn2288-2405-
dc.identifier.issn2288-2413-
dc.identifier.urihttps://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/155424-
dc.description.abstractBackground Tumor-related white matter change is detected at late stages with magnetic resonance imaging (MRI), when mass effect or prominent edema is present. We analyzed if diffusion tensor imaging (DTI) white matter change earlier than conventional MRI. Methods Twenty-six patients with gliomas (World Health Organization grade II, 5; grade III, 12; and grade IV, 9) within 2 cm from the posterior limb of the internal capsule (IC) were studied. Fifteen normal adults were enrolled as controls. Fluid attenuation inversion recovery MRI showed a high signal change at the posterior limb of the IC (HSIC) in 9 patients with grade III or IV gliomas. We classified the gliomas as WHO grade II (gliomas II), grade III or IV without HSIC [gliomas III/IV(-)] and grade III or IV with HSIC [gliomas III/IV(+)], as an indicator of the increase in the severity of the white matter changes. Fractional anisotropy (FA) and apparent diffusion coefficients (ADC) were calculated for the pyramidal tract. Tumor progression along pyramidal tract was evaluated by follow-up MRI in 16 patients at 40±18 months. Results FA showed no significant difference between gliomas II and control (p=0.694), but was lower in gliomas III/IV(-) and gliomas III/IV(+) (p<0.001). ADCs were higher in gliomas II, gliomas III/IV(-) and gliomas III/IV(+) than control (p<0.001). Tumor progression was detected in 2/16 patients. Conclusion DTI detected white matter changes that appeared to be normal in MRI. ADC changed even in low grade glioma, indicating ADC may be a better parameter for the early detection of white matter change.-
dc.format.extent7-
dc.language영어-
dc.language.isoENG-
dc.publisher대한뇌종양학회-
dc.titleWhite Matter Change Revealed by Diffusion Tensor Imaging in Gliomas-
dc.typeArticle-
dc.publisher.location대한민국-
dc.identifier.bibliographicCitationBrain Tumor Research and Treatment, v.4, no.2, pp 100 - 106-
dc.citation.titleBrain Tumor Research and Treatment-
dc.citation.volume4-
dc.citation.number2-
dc.citation.startPage100-
dc.citation.endPage106-
dc.identifier.kciidART002159283-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClasskciCandi-
dc.subject.keywordAuthorDiffusion tensor imaging-
dc.subject.keywordAuthorGlioma-
dc.subject.keywordAuthorMagnetic resonance imaging-
dc.subject.keywordAuthorWhite matter-
Files in This Item
There are no files associated with this item.
Appears in
Collections
서울 공과대학 > ETC > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lee, Jong Min photo

Lee, Jong Min
COLLEGE OF ENGINEERING (서울 바이오메디컬공학전공)
Read more

Altmetrics

Total Views & Downloads

BROWSE