Cited 0 time in
Improved motion-sensitized driven-equilibrium preparation for 3D turbo spin echo T-1 weighted imaging after gadolinium administration for the detection of brain metastases on 3T MRI
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Lee, Sangjoon | - |
| dc.contributor.author | Park, Dong Woo | - |
| dc.contributor.author | Lee, Ji Young | - |
| dc.contributor.author | Lee, Young-Jun | - |
| dc.contributor.author | Kim, Taeyoon | - |
| dc.date.accessioned | 2022-07-15T19:36:36Z | - |
| dc.date.available | 2022-07-15T19:36:36Z | - |
| dc.date.issued | 2016-00 | - |
| dc.identifier.issn | 0007-1285 | - |
| dc.identifier.issn | 1748-880X | - |
| dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/155532 | - |
| dc.description.abstract | Objective: To evaluate the clinical usefulness of an improved motion-sensitized driven-equilibrium (iMSDE) preparation for three-dimensional turbo spin echo (TSE) T1 weighted imaging after gadolinium administration in 3.0-T MRI for the detection of brain metastases compared with conventional gradient echo (C-GRE) T1 weighted imaging with gadolinium. Methods: 40 patients with suspected brain metastases underwent MR studies, including two contrast-enhanced sequences, iMSDE-TSE and C-GRE. Post-enhancement images of 14 patients with suspected metastatic brain lesions were retrospectively analyzed, and comparisons between iMSDE-TSE and C-GRE were made using the Wilcoxon signed-rank test. Results: C-GRE detected 86 metastatic lesions, whereas iMSDE-TSE detected 97, including one false-positive lesion on both sequences. 11 of 96 metastases were detected on iMSDE-TSE only. On C-GRE, 15 of 85 metastases were equivocal. There was a significant difference between C-GRE and iMSDE-TSE in terms of the number of detected lesions (p = 0.024). Notably, the interobserver agreement for diagnosing metastases and identifying non-metastases was nearly identical. Overall, iMSDE-TSE achieves higher detectability of metastatic brain lesions, especially equivocal lesions. Conclusion: Compared with C-GRE, iMSDE-TSE detected more brain metastases. This method is especially helpful in discerning equivocal metastases. | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | British Institute of Radiology | - |
| dc.title | Improved motion-sensitized driven-equilibrium preparation for 3D turbo spin echo T-1 weighted imaging after gadolinium administration for the detection of brain metastases on 3T MRI | - |
| dc.type | Article | - |
| dc.publisher.location | 영국 | - |
| dc.identifier.doi | 10.1259/bjr.20150176 | - |
| dc.identifier.scopusid | 2-s2.0-84989316489 | - |
| dc.identifier.wosid | 000378096400033 | - |
| dc.identifier.bibliographicCitation | British Journal of Radiology, v.89, no.1063 | - |
| dc.citation.title | British Journal of Radiology | - |
| dc.citation.volume | 89 | - |
| dc.citation.number | 1063 | - |
| dc.type.docType | Article | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | sci | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.relation.journalResearchArea | Radiology, Nuclear Medicine & Medical Imaging | - |
| dc.relation.journalWebOfScienceCategory | Radiology, Nuclear Medicine & Medical Imaging | - |
| dc.subject.keywordPlus | CONTRAST | - |
| dc.subject.keywordPlus | IMSDE | - |
| dc.identifier.url | https://www.birpublications.org/doi/10.1259/bjr.20150176 | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1366
COPYRIGHT © 2024 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.
