Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Incorporation of detailed eye model into polygon-mesh versions of ICRP-110 reference phantoms

Full metadata record
DC Field Value Language
dc.contributor.authorThang Tat Nguyen-
dc.contributor.authorYeom, Yeon Soo-
dc.contributor.authorKim, Han Sung-
dc.contributor.authorWang, Zhao Jun-
dc.contributor.authorHan, Min Cheol-
dc.contributor.authorKim, Chan Hyeong-
dc.contributor.authorLee, Jai Ki-
dc.contributor.authorZankl, Maria-
dc.contributor.authorPetoussi-Henss, Nina-
dc.contributor.authorBolch, Wesley E.-
dc.contributor.authorLee, Choonsik-
dc.contributor.authorChung, Beom Sun-
dc.date.accessioned2022-07-15T20:25:39Z-
dc.date.available2022-07-15T20:25:39Z-
dc.date.created2021-05-12-
dc.date.issued2015-11-
dc.identifier.issn0031-9155-
dc.identifier.urihttps://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/156033-
dc.description.abstractThe dose coefficients for the eye lens reported in ICRP 2010 Publication 116 were calculated using both a stylized model and the ICRP-110 reference phantoms, according to the type of radiation, energy, and irradiation geometry. To maintain consistency of lens dose assessment, in the present study we incorporated the ICRP-116 detailed eye model into the converted polygon-mesh (PM) version of the ICRP-110 reference phantoms. After the incorporation, the dose coefficients for the eye lens were calculated and compared with those of the ICRP-116 data. The results showed generally a good agreement between the newly calculated lens dose coefficients and the values of ICRP 2010 Publication 116. Significant differences were found for some irradiation cases due mainly to the use of different types of phantoms. Considering that the PM version of the ICRP-110 reference phantoms preserve the original topology of the ICRP-110 reference phantoms, it is believed that the PM version phantoms, along with the detailed eye model, provide more reliable and consistent dose coefficients for the eye lens.-
dc.language영어-
dc.language.isoen-
dc.publisherIOP PUBLISHING LTD-
dc.titleIncorporation of detailed eye model into polygon-mesh versions of ICRP-110 reference phantoms-
dc.typeArticle-
dc.contributor.affiliatedAuthorKim, Chan Hyeong-
dc.identifier.doi10.1088/0031-9155/60/22/8695-
dc.identifier.scopusid2-s2.0-84947104549-
dc.identifier.wosid000366108900008-
dc.identifier.bibliographicCitationPHYSICS IN MEDICINE AND BIOLOGY, v.60, no.22, pp.8695 - 8707-
dc.relation.isPartOfPHYSICS IN MEDICINE AND BIOLOGY-
dc.citation.titlePHYSICS IN MEDICINE AND BIOLOGY-
dc.citation.volume60-
dc.citation.number22-
dc.citation.startPage8695-
dc.citation.endPage8707-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.description.isOpenAccessY-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaEngineering-
dc.relation.journalResearchAreaRadiology, Nuclear Medicine & Medical Imaging-
dc.relation.journalWebOfScienceCategoryEngineering, Biomedical-
dc.relation.journalWebOfScienceCategoryRadiology, Nuclear Medicine & Medical Imaging-
dc.subject.keywordPlusDOSE CONVERSION COEFFICIENTS-
dc.subject.keywordPlusCOLOR SLICE IMAGES-
dc.subject.keywordPlusELECTRON EXPOSURE-
dc.subject.keywordPlusRADIATION-
dc.subject.keywordPlusCATARACT-
dc.subject.keywordAuthorICRP reference phantom-
dc.subject.keywordAuthordetailed eye model-
dc.subject.keywordAuthorpolygon-mesh phantom-
dc.subject.keywordAuthorlens dose coefficients-
dc.subject.keywordAuthorMonte Carlo-
dc.identifier.urlhttps://iopscience.iop.org/article/10.1088/0031-9155/60/22/8695-
Files in This Item
Appears in
Collections
서울 공과대학 > 서울 원자력공학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Chan Hyeong photo

Kim, Chan Hyeong
COLLEGE OF ENGINEERING (DEPARTMENT OF NUCLEAR ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE