Cited 0 time in
Monte Carlo Simulations for High-rate Fast Neutron Flux Measurements Made at the RAON Neutron Science Facility by Using MICROMEGAS
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | 황대희 | - |
| dc.contributor.author | 홍서기 | - |
| dc.contributor.author | 김재천 | - |
| dc.contributor.author | 김기동 | - |
| dc.contributor.author | 김용균 | - |
| dc.date.accessioned | 2022-07-15T20:44:53Z | - |
| dc.date.available | 2022-07-15T20:44:53Z | - |
| dc.date.issued | 2015-10 | - |
| dc.identifier.issn | 0374-4884 | - |
| dc.identifier.issn | 1976-8524 | - |
| dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/156175 | - |
| dc.description.abstract | RAON is a Korean heavy-ion accelerator complex that is planned to be built by 2021. Deuterons (53 MeV) and protons (88 MeV) accelerated by using a low-energy driver linac (SCL1) are delivered to the neutron production target in the Neutron Science Facility (NSF) to produce high-energy neutrons in the interval from 1 to 88 MeV with high fluxes of the order of 1012 n/cm2-sec. The repetition rate of the neutron beam ranges from 1 kHz to 1 MHz, and the maximum beam current is 12 μA at 1 MHz. The beam width is 1 2 ns. The high-energy and high-rate fast neutrons are used to estimate accurate neutron-induced cross sections for various nuclides at the NSF. A MICROMEGAS (MICRO Mesh Gaseous Structure), which is a gaseous detector initially developed for tracking in high-rate, high-energy physics experiments, is tentatively being considered as a neutron beam monitor. It can be used to measure both the energy distribution and the flux of the neutron beam. In this study, a MICROMEGAS detector for installation at the NSF was designed and investigated. 6Li, 10B, 235U and 238U targets are being considered as neutron/charged particle converters. For the low-energy region, 6Li(n, )t and 10B(n, )7Li are used in the energy range from thermal to 1 MeV. 235U(n,f) and 238U(n,f) reactions are used for high-energy region up to 90 MeV. All calculations are performed by using the GEANT4 toolkit. | - |
| dc.format.extent | 4 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | 한국물리학회 | - |
| dc.title | Monte Carlo Simulations for High-rate Fast Neutron Flux Measurements Made at the RAON Neutron Science Facility by Using MICROMEGAS | - |
| dc.type | Article | - |
| dc.publisher.location | 대한민국 | - |
| dc.identifier.doi | 10.3938/jkps.67.1315 | - |
| dc.identifier.scopusid | 2-s2.0-84945919129 | - |
| dc.identifier.wosid | 000364227300005 | - |
| dc.identifier.bibliographicCitation | Journal of the Korean Physical Society, v.67, no.8, pp 1315 - 1318 | - |
| dc.citation.title | Journal of the Korean Physical Society | - |
| dc.citation.volume | 67 | - |
| dc.citation.number | 8 | - |
| dc.citation.startPage | 1315 | - |
| dc.citation.endPage | 1318 | - |
| dc.identifier.kciid | ART002041593 | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | sci | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.description.journalRegisteredClass | kci | - |
| dc.relation.journalResearchArea | Physics | - |
| dc.relation.journalWebOfScienceCategory | Physics, Multidisciplinary | - |
| dc.subject.keywordPlus | DETECTOR | - |
| dc.subject.keywordAuthor | MICROMEGAS | - |
| dc.subject.keywordAuthor | Monte Carlo simulation | - |
| dc.subject.keywordAuthor | Neutron flux | - |
| dc.identifier.url | https://link.springer.com/article/10.3938%2Fjkps.67.1315 | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1366
COPYRIGHT © 2024 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.
