Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Intra- and Inter-Observer Reproducibility of Transcatheter Aortic Valve Replacement Planning Measurements by Multidetector Computed Tomography.

Authors
Heo, RanHartaigh, BriainCho, IksungValenti, ValentinaLeipsic, JonathonWong, S. ChiuSalemi, ArashMinutello, RobeBergman, GeoffreyMini, James K.
Issue Date
Sep-2015
Publisher
I C R PUBLISHERS
Citation
JOURNAL OF HEART VALVE DISEASE, v.24, no.5, pp.560 - 569
Indexed
SCIE
SCOPUS
Journal Title
JOURNAL OF HEART VALVE DISEASE
Volume
24
Number
5
Start Page
560
End Page
569
URI
https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/156358
ISSN
0966-8519
Abstract
BACKGROUND AND AIM OF THE STUDY: Multidetector computed tomography (MDCT) is widely used for transcatheter aortic valve replacement (TAVR) planning, and its use predicts and prevents complications. To date, the reproducibility of aortoiliofemoral measurements and prediction of fluoroscopic angles for TAVR deployment remain inadequately studied. METHODS: Twenty-five consecutive patients (six males, 19 females; mean age 81.1 years) undergoing pre-procedural evaluation for TAVR were studied for 74 separate variables by MDCT. Two experienced readers made repeated measurements of the diameter and area of the aortic annulus, the aortic root at the level of the sinuses of Valsalva, sinotubular junction, and ascending aorta, and the diameters of peripheral vessels at the level of the distal abdominal aorta, and the iliofemoral arteries. A fluoroscopic angle prediction was obtained for left anterior oblique (LAO) 0 degrees, 20 degrees and 30 degrees projections. Pearson's correlation coefficient (r) was obtained, and intra-class correlation coefficients and Bland-Altman plots were generated to examine agreements, respectively. RESULTS: The mean aortic valve area was 0.7 cm2. Each measurement generally showed good intra- and inter-observer reproducibility. The mean difference between readers was -0.3 mm for mean annular diameter and 3.6 mm2 for annular area. The area- derived diameter showed better reproducibility than the mean diameter (ICC 0.87, 0.84). However, the right coronary artery height showed poor inter-observer agreement (ICC 0.48). Angle predictions for 0 degrees, 20 degrees and 30 degrees-LAO were reproducible within and between readers (ICC 0.68-0.96 and 0.75-0.85). Qualitative assessments were also reliable between readers. CONCLUSION: Inter- and intra-observer measurements of the pre-TAVR planning parameters are reliable, with generally a high degree of agreement.
Files in This Item
There are no files associated with this item.
Appears in
Collections
서울 의과대학 > 서울 내과학교실 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Heo, Ran photo

Heo, Ran
COLLEGE OF MEDICINE (DEPARTMENT OF INTERNAL MEDICINE)
Read more

Altmetrics

Total Views & Downloads

BROWSE