End effect analysis with various axial burnup distributions in high density spent fuel storage racks
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Park, Chang Je | - |
dc.contributor.author | Park, Hwa Gyu | - |
dc.contributor.author | Shon, Hee Dong | - |
dc.contributor.author | Hong, Ser Gi | - |
dc.contributor.author | Lee, Yongdeok | - |
dc.date.accessioned | 2022-07-15T21:56:44Z | - |
dc.date.available | 2022-07-15T21:56:44Z | - |
dc.date.created | 2021-05-13 | - |
dc.date.issued | 2015-07 | - |
dc.identifier.issn | 03064549 | - |
dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/156772 | - |
dc.description.abstract | End effect of spent fuel comes from the difference between uniform and actual axial burnup distributions of fuel assemblies. It is significant to control the criticality safety in spent fuel storage and transportation. This work is focused on estimation of end effect in the spent fuel of light water reactor for the spent fuel storage rack region-II. High and low bumups of corresponding different uranium enrichments are taken into consideration to analyze the end effect with different axial burnup distributions such as uniform, MOC and EOC profiles. Two types of fuel assemblies such as CE type and Westinghouse type are considered. The whole calculations have been carried out by using the SCALE6 code including ORIGEN-5 and KENO-Va. | - |
dc.language | 영어 | - |
dc.language.iso | en | - |
dc.publisher | PERGAMON-ELSEVIER SCIENCE LTD | - |
dc.title | End effect analysis with various axial burnup distributions in high density spent fuel storage racks | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Hong, Ser Gi | - |
dc.identifier.doi | 10.1016/j.anucene.2015.01.042 | - |
dc.identifier.scopusid | 2-s2.0-84939954516 | - |
dc.identifier.wosid | 000353929200020 | - |
dc.identifier.bibliographicCitation | ANNALS OF NUCLEAR ENERGY, v.81, pp.174 - 178 | - |
dc.relation.isPartOf | ANNALS OF NUCLEAR ENERGY | - |
dc.citation.title | ANNALS OF NUCLEAR ENERGY | - |
dc.citation.volume | 81 | - |
dc.citation.startPage | 174 | - |
dc.citation.endPage | 178 | - |
dc.type.rims | ART | - |
dc.type.docType | 정기 학술지(note) | - |
dc.description.journalClass | 1 | - |
dc.description.isOpenAccess | N | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Nuclear Science & Technology | - |
dc.relation.journalWebOfScienceCategory | Nuclear Science & Technology | - |
dc.subject.keywordAuthor | End effect | - |
dc.subject.keywordAuthor | Axial burnup | - |
dc.subject.keywordAuthor | Spent fuel | - |
dc.subject.keywordAuthor | Region-II | - |
dc.subject.keywordAuthor | ORIGEN | - |
dc.subject.keywordAuthor | KENO | - |
dc.identifier.url | https://www.sciencedirect.com/science/article/pii/S0306454915000936?via%3Dihub | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1365
COPYRIGHT © 2021 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.