dc.description.abstractIn this study, material tests were performed on the masonry specimens constructed with bricks and mortar used in Korea. The specimens included two types of thickness(0.5B and 1.0B) and physical conditions (good and poor). It was shown that 1.0B specimens have 3.2~1.8 times larger shear strength than 0.5B specimens and shear strength of specimens in poor condition was 66%~38% of those in good condition. Average shear stress of masonry-infills was calculated from previous experimental studies, and relationships with failure mode, material strength of masonry, aspect ratio, and frame-to-infill strength ratio were investigated. In addition, the effects of masonry strength on the seismic performance of a masonry-infilled frame was studied using a simple example building. It can be seen that the obtained average shear stress were considerably higher than the default masonry shear strength recommended by the ASCE 41, and low values the strength of masonry does not guarantee conservative evaluation results due to the early shear failure of frame members.-
dc.language한국어-
dc.language.isoko-
dc.publisher한국지진공학회-
dc.title조적채움벽의 전단강도에 따른 채움벽골조의 내진성능-
dc.title.alternativeRelation between Shear Strength of Masonry infills and Seismic Performance of Masonry-infilled Frames-
dc.typeArticle-
dc.contributor.affiliatedAuthor유은종-
dc.identifier.doi10.5000/EESK.2015.19.4.173-
dc.identifier.bibliographicCitation한국지진공학회논문집, v.19, no.4, pp.173 - 181-
dc.relation.isPartOf한국지진공학회논문집-
dc.citation.title한국지진공학회논문집-
dc.citation.volume19-
dc.citation.number4-
dc.citation.startPage173-
dc.citation.endPage181-
dc.type.rimsART-
dc.identifier.kciidART002004909-
dc.description.journalClass2-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClasskci-
dc.subject.keywordAuthorMasonry-infilled frame-
dc.subject.keywordAuthorShear strength of masonry-
dc.subject.keywordAuthorSeismic performance-
dc.identifier.urlhttp://www.eesk-j.or.kr/journal/article.php?code=30642-
Files in This Item
Go to Link
Appears in
Collections
서울 공과대학 > 서울 건축공학부 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Yu, Eun Jong photo

Yu, Eun Jong
COLLEGE OF ENGINEERING (SCHOOL OF ARCHITECTURAL ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE