Comparisons of the Pentax-AWS, Glidescope, and Macintosh Laryngoscopes for Intubation Performance during Mechanical Chest Compressions in Left Lateral Tilt: A Randomized Simulation Study of Maternal Cardiopulmonary Resuscitation
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Lee, Sanghyun | - |
dc.contributor.author | Kim, Wonhee | - |
dc.contributor.author | Kang, Hyunggoo | - |
dc.contributor.author | Oh, Jaehoon | - |
dc.contributor.author | Lim, Tae Ho | - |
dc.contributor.author | Lee, Yoonjae | - |
dc.contributor.author | Kim, Changsun | - |
dc.contributor.author | Cho, Jun Hwi | - |
dc.date.accessioned | 2022-07-15T22:29:20Z | - |
dc.date.available | 2022-07-15T22:29:20Z | - |
dc.date.created | 2021-05-12 | - |
dc.date.issued | 2015-06 | - |
dc.identifier.issn | 2314-6133 | - |
dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/157053 | - |
dc.description.abstract | Purpose. Rapid advanced airway management is important in maternal cardiopulmonary resuscitation (CPR). This study aimed to compare intubation performances among Pentax-AWS (AWS), Glidescope (GVL), and Macintosh laryngoscope (MCL) during mechanical chest compression in 15 degrees and 30 degrees left lateral tilt. Methods. In 19 emergency physicians, a prospective randomized crossover study was conducted to examine the three laryngoscopes. Primary outcomes were the intubation time and the success rate for intubation. Results. The median intubation time using AWS was shorter than that of GVL and MCL in both tilt degrees. The time to visualize the glottic view in GVL and AWS was significantly lower than that of MCL (all P < 0.05), whereas there was no significant difference between the two video laryngoscopes (in 15 degrees tilt, P = 1; in 30 degrees tilt, P = 0.71). The progression of tracheal tube using AWS was faster than that of MCL and GVL in both degrees (all P < 0.001). Intubations using AWS and GVL showed higher success rate than that of Macintosh laryngoscopes. Conclusions. The AWS could be an appropriate laryngoscope for airway management of pregnant women in tilt CPR considering intubation time and success rate. | - |
dc.language | 영어 | - |
dc.language.iso | en | - |
dc.publisher | HINDAWI LTD | - |
dc.title | Comparisons of the Pentax-AWS, Glidescope, and Macintosh Laryngoscopes for Intubation Performance during Mechanical Chest Compressions in Left Lateral Tilt: A Randomized Simulation Study of Maternal Cardiopulmonary Resuscitation | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Kang, Hyunggoo | - |
dc.contributor.affiliatedAuthor | Oh, Jaehoon | - |
dc.contributor.affiliatedAuthor | Lim, Tae Ho | - |
dc.contributor.affiliatedAuthor | Kim, Changsun | - |
dc.identifier.doi | 10.1155/2015/975649 | - |
dc.identifier.scopusid | 2-s2.0-84934301389 | - |
dc.identifier.wosid | 000357208500001 | - |
dc.identifier.bibliographicCitation | BIOMED RESEARCH INTERNATIONAL, v.2015, pp.1 - 8 | - |
dc.relation.isPartOf | BIOMED RESEARCH INTERNATIONAL | - |
dc.citation.title | BIOMED RESEARCH INTERNATIONAL | - |
dc.citation.volume | 2015 | - |
dc.citation.startPage | 1 | - |
dc.citation.endPage | 8 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.description.journalClass | 1 | - |
dc.description.isOpenAccess | N | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Biotechnology & Applied Microbiology | - |
dc.relation.journalResearchArea | Research & Experimental Medicine | - |
dc.relation.journalWebOfScienceCategory | Biotechnology & Applied Microbiology | - |
dc.relation.journalWebOfScienceCategory | Medicine, Research & Experimental | - |
dc.subject.keywordPlus | CARDIAC-ARREST | - |
dc.subject.keywordPlus | PREGNANT PATIENT | - |
dc.subject.keywordPlus | QUALITY | - |
dc.subject.keywordPlus | DISPLACEMENT | - |
dc.subject.keywordPlus | DESATURATION | - |
dc.subject.keywordPlus | GUIDELINES | - |
dc.subject.keywordPlus | RESCUERS | - |
dc.subject.keywordPlus | POSITION | - |
dc.identifier.url | https://www.hindawi.com/journals/bmri/2015/975649/ | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1365
COPYRIGHT © 2021 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.