Cited 0 time in
외기전담 시스템의 지역별 최적 시스템 구성 및 에너지 소비 특성
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | 김희정 | - |
| dc.contributor.author | 윤동섭 | - |
| dc.contributor.author | 정재원 | - |
| dc.date.accessioned | 2022-07-15T23:12:29Z | - |
| dc.date.available | 2022-07-15T23:12:29Z | - |
| dc.date.created | 2021-05-14 | - |
| dc.date.issued | 2015-04 | - |
| dc.identifier.issn | 2287-5786 | - |
| dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/157382 | - |
| dc.description.abstract | Dedicated outdoor air system (DOAS) introduce 100% outdoor air into building to enhance ventilation and control humidity of inner space. According to usage and ambient condition, various DOAS configurations exist. Therefor, purpose of this paper is to find appropriate DOAS configurations for 3 sites in korea and analyse energy saving potentials. 6 DOAS configurations were collected to compare energy consumptions in Seoul, Kangneung and Mokpo. With building loads from TRNSYS 17 program using TMY2, energy consumptions of heating coil, chiller and fans were calculated in addition to sensible loads of DOAS and parallel cooling system according to operation modes of each configuration. As a result, appropriate DOAS configuration for each site's condition derived. | - |
| dc.language | 한국어 | - |
| dc.language.iso | ko | - |
| dc.publisher | 대한건축학회 | - |
| dc.title | 외기전담 시스템의 지역별 최적 시스템 구성 및 에너지 소비 특성 | - |
| dc.title.alternative | Optimum Dedicated Outdoor Air system for Korea and energy consumption characteristics | - |
| dc.type | Article | - |
| dc.contributor.affiliatedAuthor | 정재원 | - |
| dc.identifier.bibliographicCitation | 대한건축학회 춘계학술발표대회논문집, v.35, no.1, pp.221 - 222 | - |
| dc.relation.isPartOf | 대한건축학회 춘계학술발표대회논문집 | - |
| dc.citation.title | 대한건축학회 춘계학술발표대회논문집 | - |
| dc.citation.volume | 35 | - |
| dc.citation.number | 1 | - |
| dc.citation.startPage | 221 | - |
| dc.citation.endPage | 222 | - |
| dc.type.rims | ART | - |
| dc.type.docType | Proceeding | - |
| dc.description.journalClass | 2 | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | other | - |
| dc.subject.keywordAuthor | 외기전담 시스템 | - |
| dc.subject.keywordAuthor | 에너지 절감 | - |
| dc.subject.keywordAuthor | Dedicated outdoor air system (DOAS) | - |
| dc.subject.keywordAuthor | Energy consumption | - |
| dc.identifier.url | https://www.dbpia.co.kr/journal/articleDetail?nodeId=NODE06267385 | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1366
COPYRIGHT © 2024 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.