Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

시뮬레이션을 이용한 공동주택에서의 플러쉬아웃 효과 평가

Full metadata record
DC Field Value Language
dc.contributor.author이기용-
dc.contributor.author김기한-
dc.contributor.author박준석-
dc.date.accessioned2022-07-15T23:15:51Z-
dc.date.available2022-07-15T23:15:51Z-
dc.date.created2021-05-14-
dc.date.issued2015-04-
dc.identifier.issn2287-5786-
dc.identifier.urihttps://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/157431-
dc.description.abstractStudies on the sick building syndrome (SBS) have been carried out actively recently, along with increasing interests in health by improved the public welfare. In order to mitigate the SBS, the Korean government obligates to perform flush-out before the occupancy when newly constructing more than 500 units of multi-family residential buildings in Korea. In this study, we evaluated an effect of flush-out using indoor air quality simulation to figure out how indoor air pollution emissions could be reduced by a performing period, a supply air volume, and indoor temperature and relative humidity during the flush-out. As a result, it revealed that the flush-out should be performed at least 14 days to reduce the indoor air pollution more than a half. In addition, indoor temperature around 20°C and relative humidity around 50% were shown less significant factors affecting indoor air pollution reductions during the flush-out.-
dc.language한국어-
dc.language.isoko-
dc.publisher대한건축학회-
dc.title시뮬레이션을 이용한 공동주택에서의 플러쉬아웃 효과 평가-
dc.title.alternativeAn Evaluation of Flush-out Effect on Indoor Air Quality in Muti-family Residential Buildings Using Simulation-
dc.typeArticle-
dc.contributor.affiliatedAuthor박준석-
dc.identifier.bibliographicCitation대한건축학회 춘계학술발표대회논문집, v.35, no.1, pp.273 - 274-
dc.relation.isPartOf대한건축학회 춘계학술발표대회논문집-
dc.citation.title대한건축학회 춘계학술발표대회논문집-
dc.citation.volume35-
dc.citation.number1-
dc.citation.startPage273-
dc.citation.endPage274-
dc.type.rimsART-
dc.type.docTypeProceeding-
dc.description.journalClass2-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassother-
dc.subject.keywordAuthor플러쉬아웃-
dc.subject.keywordAuthor실내공기질-
dc.subject.keywordAuthor시뮬레이션-
dc.subject.keywordAuthor공동주택-
dc.subject.keywordAuthor환기-
dc.subject.keywordAuthorFlush-out-
dc.subject.keywordAuthorIndoor Air Quality (IAQ)-
dc.subject.keywordAuthorSimulation-
dc.subject.keywordAuthorMulti-family Residential Buildings-
dc.subject.keywordAuthorVentilation-
dc.identifier.urlhttps://www.dbpia.co.kr/journal/articleDetail?nodeId=NODE06267360-
Files in This Item
Go to Link
Appears in
Collections
서울 공과대학 > 서울 건축공학부 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Park, Jun Seok photo

Park, Jun Seok
COLLEGE OF ENGINEERING (SCHOOL OF ARCHITECTURAL ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE