Cited 0 time in
Experimental determination of the characteristics of physico-chemical particles in air-scouring-membrane (microfiltration) backwash water produced during drinking water treatment
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Park, No-Suk | - |
| dc.contributor.author | Kang, Moon-Sun | - |
| dc.contributor.author | Jeong, Woochang | - |
| dc.contributor.author | Kim, Jong-Oh | - |
| dc.date.accessioned | 2022-07-16T00:33:06Z | - |
| dc.date.available | 2022-07-16T00:33:06Z | - |
| dc.date.issued | 2015-02 | - |
| dc.identifier.issn | 0263-8762 | - |
| dc.identifier.issn | 1744-3563 | - |
| dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/157982 | - |
| dc.description.abstract | We conducted this study to investigate the physico-chemical characteristics of air-scouring-membrane (microfiltration; MF) backwash water produced by an actual drinking water treatment plant. Visual observations were made on the settling behavior (settlability) of backwash water obtained from both an air-scouring membrane and a rapid sand filter. The settling velocity of backwash water was much slower for the membrane-derived backwash water than the rapid sand filter-derived backwash water. Further, zeta-potential measurements indicated that even though polyaluminum cation coagulant was injected and mixed with the raw water before the MF membrane process, the zeta-potential value of the backwash water was reduced to that of raw water. Particle analysis revealed that the average particle size of the MF membrane backwash water was smaller than that of the rapid sand filter backwash water. | - |
| dc.format.extent | 7 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | Institute of Chemical Engineers | - |
| dc.title | Experimental determination of the characteristics of physico-chemical particles in air-scouring-membrane (microfiltration) backwash water produced during drinking water treatment | - |
| dc.type | Article | - |
| dc.publisher.location | 네델란드 | - |
| dc.identifier.doi | 10.1016/j.cherd.2014.10.012 | - |
| dc.identifier.scopusid | 2-s2.0-84922211178 | - |
| dc.identifier.wosid | 000350194500067 | - |
| dc.identifier.bibliographicCitation | Chemical Engineering Research and Design, v.94, pp 714 - 720 | - |
| dc.citation.title | Chemical Engineering Research and Design | - |
| dc.citation.volume | 94 | - |
| dc.citation.startPage | 714 | - |
| dc.citation.endPage | 720 | - |
| dc.type.docType | Article | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | sci | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.relation.journalResearchArea | Engineering | - |
| dc.relation.journalWebOfScienceCategory | Engineering, Chemical | - |
| dc.subject.keywordPlus | FILTRATION CHARACTERISTICS | - |
| dc.subject.keywordPlus | COAGULATION PRETREATMENT | - |
| dc.subject.keywordPlus | CHARGE NEUTRALIZATION | - |
| dc.subject.keywordPlus | FLOC SIZE | - |
| dc.subject.keywordPlus | PRECIPITATION | - |
| dc.subject.keywordPlus | PERFORMANCE | - |
| dc.subject.keywordPlus | REMOVAL | - |
| dc.subject.keywordPlus | SYSTEM | - |
| dc.subject.keywordAuthor | Air-scouring-membrane backwash water | - |
| dc.subject.keywordAuthor | Settling behavior (settlability) | - |
| dc.subject.keywordAuthor | Zeta-potential | - |
| dc.subject.keywordAuthor | Particle analysis | - |
| dc.identifier.url | https://www.sciencedirect.com/science/article/pii/S0263876214004547?via%3Dihub | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1366
COPYRIGHT © 2024 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.
