Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

A New Chest Compression Depth Feedback Algorithm for High-Quality CPR Based on Smartphone

Full metadata record
DC Field Value Language
dc.contributor.authorSong, Yeongtak-
dc.contributor.authorOh, Jaehoon-
dc.contributor.authorChee, Youngjoon-
dc.date.accessioned2022-07-16T01:00:40Z-
dc.date.available2022-07-16T01:00:40Z-
dc.date.created2021-05-12-
dc.date.issued2015-01-
dc.identifier.issn1530-5627-
dc.identifier.urihttps://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/158143-
dc.description.abstractBackground: Although many smartphone application (app) programs provide education and guidance for basic life support, they do not commonly provide feedback on the chest compression depth (CCD) and rate. The validation of its accuracy has not been reported to date. This study was a feasibility assessment of use of the smartphone as a CCD feedback device. In this study, we proposed the concept of a new real-time CCD estimation algorithm using a smartphone and evaluated the accuracy of the algorithm. Materials and Methods: Using the double integration of the acceleration signal, which was obtained from the accelerometer in the smartphone, we estimated the CCD in real time. Based on its periodicity, we removed the bias error from the accelerometer. To evaluate this instrument's accuracy, we used a potentiometer as the reference depth measurement. The evaluation experiments included three levels of CCD (insufficient, adequate, and excessive) and four types of grasping orientations with various compression directions. We used the difference between the reference measurement and the estimated depth as the error. The error was calculated for each compression. Results: When chest compressions were performed with adequate depth for the patient who was lying on a flat floor, the mean (standard deviation) of the errors was 1.43 (1.00) mm. When the patient was lying on an oblique floor, the mean (standard deviation) of the errors was 3.13 (1.88) mm. Conclusions: The error of the CCD estimation was tolerable for the algorithm to be used in the smartphone-based CCD feedback app to compress more than 51 mm, which is the 2010 American Heart Association guideline.-
dc.language영어-
dc.language.isoen-
dc.publisherMARY ANN LIEBERT, INC-
dc.titleA New Chest Compression Depth Feedback Algorithm for High-Quality CPR Based on Smartphone-
dc.typeArticle-
dc.contributor.affiliatedAuthorOh, Jaehoon-
dc.identifier.doi10.1089/tmj.2014.0051-
dc.identifier.scopusid2-s2.0-84921472132-
dc.identifier.wosid000348302800006-
dc.identifier.bibliographicCitationTELEMEDICINE AND E-HEALTH, v.21, no.1, pp.36 - 41-
dc.relation.isPartOfTELEMEDICINE AND E-HEALTH-
dc.citation.titleTELEMEDICINE AND E-HEALTH-
dc.citation.volume21-
dc.citation.number1-
dc.citation.startPage36-
dc.citation.endPage41-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaHealth Care Sciences & Services-
dc.relation.journalWebOfScienceCategoryHealth Care Sciences & Services-
dc.subject.keywordPlusCARDIOPULMONARY-RESUSCITATION-
dc.subject.keywordPlusIMPROVES-
dc.subject.keywordAuthorcardiopulmonary resuscitation-
dc.subject.keywordAuthorchest compression depth-
dc.subject.keywordAuthoraccelerometer-
dc.subject.keywordAuthorsmartphone-
dc.identifier.urlhttps://www.liebertpub.com/doi/10.1089/tmj.2014.0051-
Files in This Item
Go to Link
Appears in
Collections
서울 의과대학 > 서울 응급의학교실 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Oh, Jae hoon photo

Oh, Jae hoon
COLLEGE OF MEDICINE (DEPARTMENT OF EMERGENCY MEDICINE)
Read more

Altmetrics

Total Views & Downloads