Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Fracture of the Greater Trochanter during Closed Reduction of Obturator Type Hip Dislocationopen access

Authors
양재혁Dilbans Singh Pandher오광준
Issue Date
Dec-2014
Publisher
대한고관절학회
Keywords
Greater trochanter; Avulsion fracture; Obturator (Inferior) type hip dislocation; Closed reduction
Citation
Hip and Pelvis, v.26, no.4, pp.275 - 278
Indexed
KCI
Journal Title
Hip and Pelvis
Volume
26
Number
4
Start Page
275
End Page
278
URI
https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/158399
DOI
10.5371/hp.2014.26.4.275
ISSN
2287-3260
Abstract
Obturator (Inferior) type dislocation of the hip joint is a rare and the fracture of greater trochanter during closed reduction for it has never been reported in literature. In this report, we present a case of a fracture of greater trochanter during difficult closed reduction which required operative fixation. Surgeons need to be aware of this complication and excessive force for reduction should be avoided when treating of this type dislocation.
Files in This Item
Appears in
Collections
서울 의과대학 > 서울 정형외과학교실 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE