Cited 0 time in
Isolated Acetabular Revision With Ceramic-on-Ceramic Bearings Using a Ceramic Head With a Metal Sleeve
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Kim, Yeesuk | - |
| dc.contributor.author | Kim, Young-Ho | - |
| dc.contributor.author | Hwang, Kyu-Tae | - |
| dc.contributor.author | Choi, Il-Yong | - |
| dc.date.accessioned | 2022-07-16T01:35:45Z | - |
| dc.date.available | 2022-07-16T01:35:45Z | - |
| dc.date.issued | 2014-12 | - |
| dc.identifier.issn | 0883-5403 | - |
| dc.identifier.issn | 1532-8406 | - |
| dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/158462 | - |
| dc.description.abstract | The purpose of this study is to evaluate results of isolated acetabular revision with ceramic-on-ceramic bearings using a ceramic head with a metal sleeve. A retrospective review of fifty-three hips was performed. The mean patient age was 49.9 years and the mean follow-up period was 5.7 years. The mean modified Harris hip score improved from 47.5, pre-operatively, to 84.7 at the time of last follow-up (P < 0.001). Two patients reported squeaking of the hip. Three patients experienced loosening cup, necessitating re-revision surgery. There was a significant difference of acetabular bone defect between loose cup group and stable cup group (P = 0.018). There were no ceramic fractures and no osteolysis. The survival rate of the acetabular cup at the mid-term follow-up was 94.3%. In conclusion, ceramic head with a metal sleeve can be a reliable option for isolated acetabular revision. | - |
| dc.format.extent | 4 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | Churchill Livingstone | - |
| dc.title | Isolated Acetabular Revision With Ceramic-on-Ceramic Bearings Using a Ceramic Head With a Metal Sleeve | - |
| dc.type | Article | - |
| dc.publisher.location | 미국 | - |
| dc.identifier.doi | 10.1016/j.arth.2014.03.007 | - |
| dc.identifier.scopusid | 2-s2.0-84912575322 | - |
| dc.identifier.wosid | 000345150900039 | - |
| dc.identifier.bibliographicCitation | Journal of Arthroplasty, v.29, no.12, pp 2420 - 2423 | - |
| dc.citation.title | Journal of Arthroplasty | - |
| dc.citation.volume | 29 | - |
| dc.citation.number | 12 | - |
| dc.citation.startPage | 2420 | - |
| dc.citation.endPage | 2423 | - |
| dc.type.docType | Article | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.relation.journalResearchArea | Orthopedics | - |
| dc.relation.journalWebOfScienceCategory | Orthopedics | - |
| dc.subject.keywordPlus | TOTAL HIP-ARTHROPLASTY | - |
| dc.subject.keywordPlus | 11-YEAR FOLLOW-UP | - |
| dc.subject.keywordPlus | FEMORAL COMPONENTS | - |
| dc.subject.keywordPlus | WEAR | - |
| dc.subject.keywordPlus | REPLACEMENT | - |
| dc.subject.keywordPlus | FAILURE | - |
| dc.subject.keywordPlus | OSTEOLYSIS | - |
| dc.subject.keywordPlus | RETRIEVAL | - |
| dc.subject.keywordPlus | MINIMUM | - |
| dc.subject.keywordAuthor | hip | - |
| dc.subject.keywordAuthor | revision hip arthroplasty | - |
| dc.subject.keywordAuthor | ceramic | - |
| dc.subject.keywordAuthor | metal sleeve | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1366
COPYRIGHT © 2024 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.
