Cited 0 time in
Performance evaluation of advanced industrial SPECT system with diverging collimator
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Park, Jang Guen | - |
| dc.contributor.author | Jung, Sung-Hee | - |
| dc.contributor.author | Kim, Jong Bum | - |
| dc.contributor.author | Moon, Jinho | - |
| dc.contributor.author | Yeom, Yeon Soo | - |
| dc.contributor.author | Kim, Chan Hyeong | - |
| dc.date.accessioned | 2022-07-16T01:36:12Z | - |
| dc.date.available | 2022-07-16T01:36:12Z | - |
| dc.date.issued | 2014-12 | - |
| dc.identifier.issn | 0969-8043 | - |
| dc.identifier.issn | 1872-9800 | - |
| dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/158467 | - |
| dc.description.abstract | An advanced industrial SPECT system with 12-fold-array diverging collimator was developed for flow visualization in industrial reactors and was discussed in the previous study. The present paper describes performance evaluation of the SPECT system under both static- and dynamic- flow conditions. Under static conditions, the movement of radiotracer inside the test reactor was compared with that of color tracer (blue ink) captured with a high-speed camera. The comparison of the reconstructed images obtained with the radiotracer and the SPECT system showed fairly good agreement with video-frames of the color tracer obtained with the camera. Based on the results of the performance evaluation, it is concluded that the SPECT system is suitable for investigation and visualization of flows in industrial flow reactors. | - |
| dc.format.extent | 6 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | Pergamon Press Ltd. | - |
| dc.title | Performance evaluation of advanced industrial SPECT system with diverging collimator | - |
| dc.type | Article | - |
| dc.publisher.location | 영국 | - |
| dc.identifier.doi | 10.1016/j.apradiso.2014.07.020 | - |
| dc.identifier.scopusid | 2-s2.0-84907350088 | - |
| dc.identifier.wosid | 000345477700022 | - |
| dc.identifier.bibliographicCitation | Applied Radiation and Isotopes, v.94, pp 125 - 130 | - |
| dc.citation.title | Applied Radiation and Isotopes | - |
| dc.citation.volume | 94 | - |
| dc.citation.startPage | 125 | - |
| dc.citation.endPage | 130 | - |
| dc.type.docType | Article | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | sci | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.relation.journalResearchArea | Chemistry | - |
| dc.relation.journalResearchArea | Nuclear Science & Technology | - |
| dc.relation.journalResearchArea | Radiology, Nuclear Medicine & Medical Imaging | - |
| dc.relation.journalWebOfScienceCategory | Chemistry, Inorganic & Nuclear | - |
| dc.relation.journalWebOfScienceCategory | Nuclear Science & Technology | - |
| dc.relation.journalWebOfScienceCategory | Radiology, Nuclear Medicine & Medical Imaging | - |
| dc.subject.keywordPlus | TOMOGRAPH | - |
| dc.subject.keywordAuthor | Industrial SPECT | - |
| dc.subject.keywordAuthor | Industrial process diagnosis | - |
| dc.subject.keywordAuthor | Gamma radiation | - |
| dc.subject.keywordAuthor | Diverging collimator | - |
| dc.subject.keywordAuthor | Radiotracer | - |
| dc.subject.keywordAuthor | CsI(Tl) | - |
| dc.identifier.url | https://www.sciencedirect.com/science/article/pii/S0969804314002991?via%3Dihub | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1366
COPYRIGHT © 2024 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.