Performance evaluation of advanced industrial SPECT system with diverging collimator

Full metadata record
DC Field Value Language
dc.contributor.authorPark, Jang Guen-
dc.contributor.authorJung, Sung-Hee-
dc.contributor.authorKim, Jong Bum-
dc.contributor.authorMoon, Jinho-
dc.contributor.authorYeom, Yeon Soo-
dc.contributor.authorKim, Chan Hyeong-
dc.date.accessioned2022-07-16T01:36:12Z-
dc.date.available2022-07-16T01:36:12Z-
dc.date.created2021-05-12-
dc.date.issued2014-12-
dc.identifier.issn0969-8043-
dc.identifier.urihttps://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/158467-
dc.description.abstractAn advanced industrial SPECT system with 12-fold-array diverging collimator was developed for flow visualization in industrial reactors and was discussed in the previous study. The present paper describes performance evaluation of the SPECT system under both static- and dynamic- flow conditions. Under static conditions, the movement of radiotracer inside the test reactor was compared with that of color tracer (blue ink) captured with a high-speed camera. The comparison of the reconstructed images obtained with the radiotracer and the SPECT system showed fairly good agreement with video-frames of the color tracer obtained with the camera. Based on the results of the performance evaluation, it is concluded that the SPECT system is suitable for investigation and visualization of flows in industrial flow reactors.-
dc.language영어-
dc.language.isoen-
dc.publisherPERGAMON-ELSEVIER SCIENCE LTD-
dc.titlePerformance evaluation of advanced industrial SPECT system with diverging collimator-
dc.typeArticle-
dc.contributor.affiliatedAuthorKim, Chan Hyeong-
dc.identifier.doi10.1016/j.apradiso.2014.07.020-
dc.identifier.scopusid2-s2.0-84907350088-
dc.identifier.wosid000345477700022-
dc.identifier.bibliographicCitationAPPLIED RADIATION AND ISOTOPES, v.94, pp.125 - 130-
dc.relation.isPartOfAPPLIED RADIATION AND ISOTOPES-
dc.citation.titleAPPLIED RADIATION AND ISOTOPES-
dc.citation.volume94-
dc.citation.startPage125-
dc.citation.endPage130-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaChemistry-
dc.relation.journalResearchAreaNuclear Science & Technology-
dc.relation.journalResearchAreaRadiology, Nuclear Medicine & Medical Imaging-
dc.relation.journalWebOfScienceCategoryChemistry, Inorganic & Nuclear-
dc.relation.journalWebOfScienceCategoryNuclear Science & Technology-
dc.relation.journalWebOfScienceCategoryRadiology, Nuclear Medicine & Medical Imaging-
dc.subject.keywordPlusTOMOGRAPH-
dc.subject.keywordAuthorIndustrial SPECT-
dc.subject.keywordAuthorIndustrial process diagnosis-
dc.subject.keywordAuthorGamma radiation-
dc.subject.keywordAuthorDiverging collimator-
dc.subject.keywordAuthorRadiotracer-
dc.subject.keywordAuthorCsI(Tl)-
dc.identifier.urlhttps://www.sciencedirect.com/science/article/pii/S0969804314002991?via%3Dihub-
Files in This Item
Go to Link
Appears in
Collections
서울 공과대학 > 서울 원자력공학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Chan Hyeong photo

Kim, Chan Hyeong
COLLEGE OF ENGINEERING (DEPARTMENT OF NUCLEAR ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE